Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Fluid-structure interaction simulations in patient-specific coronary arteries with aneurysms: Viscoelastic or shear-thinning property of blood

Publicações

Fluid-structure interaction simulations in patient-specific coronary arteries with aneurysms: Viscoelastic or shear-thinning property of blood

Título
Fluid-structure interaction simulations in patient-specific coronary arteries with aneurysms: Viscoelastic or shear-thinning property of blood
Tipo
Artigo em Revista Científica Internacional
Ano
2025-06
Autores
C. Paz
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
E. Suárez
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
C. Gil
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
S.I.S. Pinto
(Autor)
FEUP
Revista
Vol. 265
ISSN: 0169-2607
Editora: Elsevier
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge
Publicação em Scopus Scopus
Classificação Científica
CORDIS: Ciências Tecnológicas > Engenharia > Engenharia mecânica ; Ciências Tecnológicas > Engenharia > Engenharia biomédica
FOS: Ciências da engenharia e tecnologias > Engenharia mecânica ; Ciências da engenharia e tecnologias > Engenharia médica
Outras Informações
Resumo (PT):
Abstract (EN): Background and Objective Coronary artery aneurysm is a progressive and often asymptomatic condition with a prevalence ranging from 0.3 % to 5 %. This condition can lead to severe and potentially fatal complications. Given the challenges of conducting experiments on real patients, numerical simulations have emerged as a valuable alternative. This study aims to enhance the accuracy of hemodynamic analysis and fluid-structure interaction assessments by incorporating the viscoelastic properties of blood, which are often overlooked, in simulations of the right coronary artery with various aneurysm morphologies. Methods This research employs numerical simulations to analyse the hemodynamics and assess the one-way coupled fluid-structure interaction within the right coronary artery. The study utilised the simplified Phan-Thien/Tanner model to represent the viscoelastic properties of blood. Different aneurysm morphologies were simulated, and the results were compared with those obtained using the widely recognised Carreau model. The analysis focused on the time-average wall-shear stress, as well as the stress and deformation experienced by the aneurysm wall. Results The hemodynamic analysis demonstrated that the simplified Phan-Thien/Tanner model produced similar flow patterns to the Carreau model but resulted in a significant reduction of approximately 50 % in the time-average wall-shear stress. This reduction aligns with previous findings. Additionally, the study revealed substantial differences in the stress and deformation of the aneurysm wall, with the simplified Phan-Thien/Tanner model proving more accuracy. The largest deformations were observed in aneurysms with incipient and fusiform shapes, particularly in the divergent section of the proximal region. In the case of saccular aneurysms, the most compromised area was identified not within the aneurysm sac itself, but in the region of the artery just upstream. Conclusions Incorporating the viscoelastic properties of blood into fluid-structure interaction simulations significantly improves the accuracy of hemodynamic and structural assessments of coronary artery aneurysms. This study underscores the importance of considering these properties when evaluating aneurysm behaviour, which could have important implications for understanding the progression and potential rupture of aneurysms, thereby guiding more effective clinical interventions.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 13
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Das mesmas áreas científicas

Numerical Study of a Thrombus Migration Risk in Aneurysm After Coil Embolization in Patient Cases: FSI Modelling (2023)
Artigo em Revista Científica Internacional
C. Paz; E. Suárez; A. Cabarcos; S.I.S. Pinto
FSI modeling on the effect of artery-aneurysm thickness and coil embolization in patient cases (2021)
Artigo em Revista Científica Internacional
C. Paz; E. Suárez; A. Cabarcos; Sónia I. S. Pinto
Semi-Automatic Construction of 3D Coronary Geometries in Hyperemia Conditions for FFR Achievement - Development of a Python Software (2025)
Artigo em Livro de Atas de Conferência Internacional
G. Rodrigues; M. Fernandes; L.C. Sousa; J. Festas; S.I.S. Pinto

Ver todas (25)

Da mesma revista

Skin Lesion Computational Diagnosis of Dermoscopic Images: Ensemble Models based on Input Feature Manipulation (2017)
Artigo em Revista Científica Internacional
Roberta B. Oliveira; Aledir S. Pereira; João Manuel R. S. Tavares
Segmentation of ultrasound images of the carotid using RANSAC and cubic splines (2011)
Artigo em Revista Científica Internacional
Rui Rocha; Aurélio Campilho; Jorge A. Silva; Elsa Azevedo; Rosa Santos
Red blood cells tracking and cell-free layer formation in a microchannel with hyperbolic contraction: A CFD model validation (2022)
Artigo em Revista Científica Internacional
Gracka, M; Lima, R; Miranda, JM; Student, S; Melka, B; Ostrowski, Z
Positive state observer for the automatic control of the depth of anesthesia-Clinical results (2019)
Artigo em Revista Científica Internacional
Filipa N. Nogueira; T. Mendonça; Maria Paula Rocha

Ver todas (35)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-08-31 às 14:53:43 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias