Fluorimetric determination of aminocaproic acid in pharmaceutical formulations using a sequential injection analysis system

Título
Fluorimetric determination of aminocaproic acid in pharmaceutical formulations using a sequential injection analysis system
Tipo
Artigo em Revista Científica Internacional
Ano
2006
Autores
Pinto, PCAG
(Autor)
FFUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Saraiva, MLMFS
(Autor)
FFUP
Santos, JLM
(Autor)
FFUP
Revista
Título: TalantaImportada do Authenticus Pesquisar Publicações da Revista
Vol. 68
Páginas: 857-862
ISSN: 0039-9140
Editora: Elsevier
Indexação
Classificação Científica
CORDIS: Ciências da Saúde
FOS: Ciências exactas e naturais > Química
Outras Informações
ID Authenticus: P-004-NPG
Resumo (PT): A sequential injection analysis (SIA) methodology for the fluorimetric determination of aminocaproic acid in pharmaceutical formulations is proposed. The developed analytical procedure is based on the derivatisation reaction of the aminocaproic primary amine with o-phthalaldehyde (OPA) and N-acetylcysteine (NAC) and fluorimetric detection of the formed product (λex = 350 nm; λem = 450 nm). The implementation of a SIA flow system allowed for the development of a simple, fast and versatile automated methodology, which exhibits evident advantages regarding the US Pharmacopoeia 24 (USP 24) reference procedure. By combining the SIA time-based sample insertion with a subsequent zone sampling approach, which permitted to select for detection of a well-defined sample zone, it was possible to implement an on-line dilution strategy that enabled the expansion of the analytical working range of the methodology, and thus its application in dissolution studies, without manifold re-configuration. Linear calibration plots were obtained for aminocaproic acid concentrations up to 6 × 10−5 mol l−1. The developed methodology exhibit a good precision, with a R.S.D. < 2.0% (n = 15) and the detection limit was 2.5 × 10−7 mol l−1. The obtained results complied with those furnished by the reference procedure with a relative deviation lower than 1.2%. No interference was found. <br> <br> Keywords: SIA; Fluorimetric detection; Dissolution test; Aminocaproic acid; On-line dilution; o-Phthalaldehyde (OPA) <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6THP-4GMJ8YF-1&_user=2460038&_coverDate=01%2F15%2F2006&_rdoc=55&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235288%232006%23999319996%23614614%23FLA%23display%23Volume)&_cdi=5288&_sort=d&_docanchor=&_ct=85&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=fdb31a8974550318f718dbc96c8867d2"> Texto integral</a> <br> <br>
Abstract (EN): A sequential injection analysis (SIA) methodology for the fluorimetric determination of aminocaproic acid in pharmaceutical formulations is proposed. The developed analytical procedure is based on the derivatisation reaction of the aminocaproic primary amine with o-phthalaldehyde (OPA) and A-acetylcysteine (NAC) and fluorimetric detection of the formed product (lambda(ex) = 350 nm; lambda(em) = 450 nm). The implementation of a SIA flow system allowed for the development of a simple, fast and versatile automated methodology, which exhibits evident advantages regarding the US Pharmacopoeia 24 (USP 24) reference procedure. By combining the SIA time-based sample insertion with a Subsequent zone sampling approach, which permitted to select for detection of a well-defined sample zone, it was possible to implement an on-line dilution strategy that enabled the expansion of the analytical working range of the methodology, and thus its application in dissolution studies, without manifold re-configuration. Linear calibration plots were obtained for aminocaproic acid concentrations up to 6 x 10(-5) mol l(-1). The developed methodology exhibit a good precision, with a R.S.D. < 2.0% (n = 15) and the detection limit was 2.5 x 10(-7) mol l(-1). The obtained results complied with those furnished by the reference procedure with a relative deviation lower than 1.2%. No interference was found.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 6
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Dos mesmos autores

A pulsed sequential injection analysis flow system for the fluorimetric determination of indomethacin in pharmaceutical preparations (2005)
Artigo em Revista Científica Internacional
Pinto, PCAG; Saraiva, MLMFS; Santos, JLM; Lima, JLFC

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM

Ver todas (159)

Da mesma revista

Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis (2016)
Outra Publicação em Revista Científica Internacional
Couto, RAS; Lima, JLFC; M. Beatriz Q. Garcia
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Flow injection based methods for fast screening of antioxidant capacity (2009)
Outra Publicação em Revista Científica Internacional
Luis M Magalhaes; Miguel Santos; Marcela A Segundo; Salette Reis; Jose L F C Lima
Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples (2012)
Outra Publicação em Revista Científica Internacional
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Teresa T S D Vasconcelos

Ver todas (193)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-03 às 23:03:34 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias