Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Flow system with electrochemical detection for determination of paracetamol in pharmaceutical preparations

Publicações

Flow system with electrochemical detection for determination of paracetamol in pharmaceutical preparations

Título
Flow system with electrochemical detection for determination of paracetamol in pharmaceutical preparations
Tipo
Artigo em Revista Científica Internacional
Ano
2006
Autores
Silva, M.L.S.
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
M. Beatriz Q. Garcia
(Autor)
FFUP
Revista
Vol. 24 2
Páginas: 261-271
ISSN: 0872-1904
Classificação Científica
FOS: Ciências médicas e da saúde > Outras ciências médicas
CORDIS: Ciências da Saúde
Outras Informações
Resumo (PT): A FIA system with electrochemical detection was developed for the automatic determination of paracetamol in pharmaceutical formulations. The analytical difficulties caused by adsorption of matrix excipients in the electrode surface were surpassed by an on-line electrochemical regeneration of the glassy carbon tubular electrode, using the carrier solution, enabling the renewal of the electrode surface in a simple and rapid way. A single channel FIA manifold was developed, which provided reproducibility of sample transport to the detector and minimized the contact time between samples and electrode surface, thus reducing its cleaning frequency and permitting a high sampling rate to be achieved. Furthermore, the physical characteristics of the electrochemical cell permitted its easy incorporation in the FIA manifold, offering robustness to the system, and allowed it to be generalized to routine analysis applications. With the optimized parameters, a linear correlation between paracetamol concentration and peak current intensity was obtained up to 4 ´ 10-4 mol L-1, with a detection limit of 2.5 ´ 10-5 mol L-1. Paracetamol was quantified in pharmaceutical dosage forms and the results were compared to those obtained for the official spectrophotometric method (BP 1998). Correlation between the results obtained by both methods was linear and no statistical difference between methods was found at the 95% confidence level. <br> <br> Keywords: paracetamol; electrochemical detection; tubular electrodes; flow system. <br> <a target="_blank" href="http://www.scielo.oces.mctes.pt/scielo.php?script=sci_abstract&pid=S0872-19042006000200008&lng=en&nrm=iso&tlng=en "> Texto integral </a> <br> <br>
Abstract (EN): A FIA system with electrochemical detection was developed for the automatic determination of paracetamol in pharmaceutical formulations. The analytical difficulties caused by adsorption of matrix excipients in the electrode surface were surpassed by an on-line electrochemical regeneration of the glassy carbon tubular electrode, using the carrier solution, enabling the renewal of the electrode surface in a simple and rapid way. A single channel FIA manifold was developed, which provided reproducibility of sample transport to the detector and minimized the contact time between samples and electrode surface, thus reducing its cleaning frequency and permitting a high sampling rate to be achieved. Furthermore, the physical characteristics of the electrochemical cell permitted its easy incorporation in the FIA manifold, offering robustness to the system, and allowed it to be generalized to routine analysis applications. With the optimized parameters, a linear correlation between paracetamol concentration and peak current intensity was obtained up to 4 ´ 10-4 mol L-1, with a detection limit of 2.5 ´ 10-5 mol L-1. Paracetamol was quantified in pharmaceutical dosage forms and the results were compared to those obtained for the official spectrophotometric method (BP 1998). Correlation between the results obtained by both methods was linear and no statistical difference between methods was found at the 95% confidence level. <br> <br> Keywords: paracetamol; electrochemical detection; tubular electrodes; flow system. <br> <a target="_blank" href="http://www.scielo.oces.mctes.pt/scielo.php?script=sci_abstract&pid=S0872-19042006000200008&lng=en&nrm=iso&tlng=en "> Full text </a> <br> <br>
Idioma: Português
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

The influence of Li on the electrochemical behaviour of pure aluminium (1989)
Artigo em Revista Científica Internacional
J. C. Fricain; M. A. Travassos; E. Leitão; C. M. Rangel; M. Barbosa; M. G. S. Ferreira
Quantification of Nickel Species in Physiological Media Using Microelectrodes (1995)
Artigo em Revista Científica Internacional
M. C. Pereira; J. P. Sousa
O efeito da soldadura na corrosão de um aço macio (1996)
Artigo em Revista Científica Internacional
Maria Cristina S. Nunes; Quitéria P. M. Silva; José Inácio F. P. Martins

Ver todas (13)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-04 às 03:18:14 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias