Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Sequential determination of salicylic and acetylsalicylic acids by amperometric multisite detection flow injection analysis.

Publicações

Sequential determination of salicylic and acetylsalicylic acids by amperometric multisite detection flow injection analysis.

Título
Sequential determination of salicylic and acetylsalicylic acids by amperometric multisite detection flow injection analysis.
Tipo
Artigo em Revista Científica Internacional
Ano
2002
Autores
Catarino RI
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Garcia MB
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Barrado E
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 85 6
Páginas: 1253-1259
ISSN: 1060-3271
Indexação
Classificação Científica
FOS: Ciências médicas e da saúde > Outras ciências médicas
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-000-MHT
Resumo (PT): An amperometric multisite detection flow injection analysis (FIA) system was developed for sequential determination of 2 analytes with a single sample injection and single detector. Tubular composite carbon electrodes with an inner diameter similar to that of the FIA manifold tubing were constructed so that measurements could be made without impairing the sample plug hydrodynamic characteristics. The electrochemical behavior of the tubular voltammetric cell in a low-dispersion FIA manifold and the behavior of the FIA system incorporating this type of voltammetric cell intended for multisite detection were evaluated by performing measurements with potassium hexacyanoferrate(II). Feasibility of the approach was demonstrated in the sequential determination of salicylic and acetylsalicylic acids in pharmaceutical products at a fixed potential of 0.98 V. The system allows sequential determination of salicylic acid concentrations ranging from 1.0 x 10(-5) to 5.0 x 10(-5) M and acetylsalicylic acid concentrations between 1.0 x 10(-3) and 5.0 x 10(-3) M with good precision on both detection sites and with relative standard deviations (RSDs) > or = 1.5% (n = 10) and 2.1% (n = 10), respectively. A comparison of these results with those of the U.S. Pharmacopeia procedure showed RSDs <5.0 and 1.0% for salicylic acid and acetylsalicylic acid, respectively. The proposed method enables 15 determinations per hour, which corresponds to the analysis of approximately 8 samples per hour. The detection limits of the methodology were approximately 3.5 x 10(-6) and 1.1 x 10(-5) M, respectively, for the first and second monitoring sites. <br> <br>
Abstract (EN): An amperometric multisite detection flow injection analysis (FIA) system was developed for sequential determination of 2 analytes with a single sample injection and single detector. Tubular composite carbon electrodes with an inner diameter similar to that of the FIA manifold tubing were constructed so that measurements could be made without impairing the sample plug hydrodynamic characteristics. The electrochemical behavior of the tubular voltammetric cell in a low-dispersion FIA manifold and the behavior of the FIA system incorporating this type of voltammetric cell intended for multisite detection were evaluated by performing measurements with potassium hexacyanoferrate(II). Feasibility of the approach was demonstrated in the sequential determination of salicylic and acetylsalicylic acids in pharmaceutical products at a fixed potential of 0.98 V. The system allows sequential determination of salicylic acid concentrations ranging from 1.0 x 10(-5) to 5.0 x 10(-5) M and acetylsalicylic acid concentrations between 1.0 x 10(-3) and 5.0 x 10(-3) M with good precision on both detection sites and with relative standard deviations (RSDs) > or = 1.5% (n = 10) and 2.1% (n = 10), respectively. A comparison of these results with those of the U.S. Pharmacopeia procedure showed RSDs <5.0 and 1.0% for salicylic acid and acetylsalicylic acid, respectively. The proposed method enables 15 determinations per hour, which corresponds to the analysis of approximately 8 samples per hour. The detection limits of the methodology were approximately 3.5 x 10(-6) and 1.1 x 10(-5) M, respectively, for the first and second monitoring sites. <br> <br>
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Validation of Biomode SA Probe4Cronobacter (TM) for the Identification of Cronobacter spp. (2019)
Artigo em Revista Científica Internacional
Cerqueira, L.; Rui Rocha; José Mário Sousa; Almeida, C; Azevedo, NF; Benjamin Bastin; Patrick Bird; M Joseph Benzinger; James Agin; David Goins; Yi Chen; Michael Brodsky; Joseph Odumoru
Use of Flow Injection Multisite Detection as a Novel Approach for Blank Signal Correction in a Spectrophotometric Determination. (2005)
Artigo em Revista Científica Internacional
Oliveira, Teresa A. C; Mesquita, Raquel B. R.; Lima, José L. F. C; Rangel, Antonio O. S. S.
Stability of Chlorophenols and Their Acetylated Derivatives in Water: Sample Storage Procedures (2014)
Artigo em Revista Científica Internacional
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Pedro N Carvalho; Teresa T S D Vasconcelos

Ver todas (10)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-19 às 05:31:30 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias