Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Indices and repeatability tests of cardiovascular function performed on the arterial distension waveform - Case study: Angiography intervention

Publicações

Indices and repeatability tests of cardiovascular function performed on the arterial distension waveform - Case study: Angiography intervention

Título
Indices and repeatability tests of cardiovascular function performed on the arterial distension waveform - Case study: Angiography intervention
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2013
Autores
Almeida, VG
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Borba, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pereira, HC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pereira, T
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Cardoso, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Correia, C
(Autor)
FCUP
Ata de Conferência Internacional
Páginas: 138-144
International Conference on Bio-Inspired Systems and Signal Processing, BIOSIGNALS 2013
Barcelona, 11 February 2013 through 14 February 2013
Indexação
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-008-B0J
Abstract (EN): The arterial distension waveform (ADW) analysis is a reliable technique for cardiovascular function assessment. The purpose of this study was to perform the pre-clinical validation of a non-invasive prototype focusing the repeatability tests and cross-relationships between different subject groups. The evaluation focused parameters retrieved from ADW: systolic peak (SP), dicrotic notch (DN), RP (reflection point) and Augmentation index (AI). One hundred and fifty one subjects (61 men and 90 women, aged between 18 and 80 years) were assigned into four groups based on their clinical characteristics. Database is constituted by healthy, hypertensive and subjects that suffer from stenosis. The cross-correlations analysis between groups allows establishing time parameterizations for each one. Furthermore, the differences between the left and right carotid artery suggest intrinsically variability for each one of the subjects. The coefficient of variation (CV) mean value obtained for all measurements was 18.58%, maximum rate of 33.7% and minimum 8.9%. The stenosis case study demonstrate the potentialities of the use of this prototype in the detection of cardiac anomalies by the monitoring of state alterations through RP, SP and DN time parameterizations with visible changes in RP and SP values (after carotid intervention RP appears later than SP, in opposition with values before intervention), while DN associated time changes little. The tests performed on the ADW showed that is possible the reliable measurement of morphological patterns changes.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-13 às 03:56:01 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico