Design and development of a multichannel potentiometer for monitoring an electrode array and its application in f ow analysis

Título
Design and development of a multichannel potentiometer for monitoring an electrode array and its application in f ow analysis
Tipo
Artigo em Revista Científica Internacional
Ano
2002
Autores
Jarbas J. R. Rohwedder
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Celio Pasquini
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ivo M. Raimundo Jr
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
M. Conceição B. S. Montenegro
(Autor)
FFUP
Alberto N. Araújo
(Autor)
FFUP
Cristina M. C. M. Couto
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 24 4
Páginas: 105-110
ISSN: 1463-9246
Indexação
Publicação em ISI Web of Science ISI Web of Science
Classificação Científica
FOS: Ciências médicas e da saúde > Outras ciências médicas
CORDIS: Ciências da Saúde
Outras Informações
Resumo (PT): A versatile potentiometer that works with electrode arrays in flow injection and/or monosegmented flow systems is described. The potentiometer is controlled by a microcomputer that allows individual, sequential multiplexed or random accesses to eight electrodes while employing only one reference electrode. The instrument was demonstrated by monitoring an array of seven flow-through ion-selective electrodes for Ag+ and for three electrodes for Cl-, Ca2+ and K+. The figures of merit of the individual and multiplexed (summed) readings of the electrode array were compared. The absolute standard deviation of the measurements made by summing the potential of two or more electrodes was maintained constant, thus improving the precision of the measurements. This result shows that an attempt to combine the signals of the electrodes to produce a more intense signal in the Hadamard strategy is feasible and accompanied by a proportional improvement in the precision of individual measurements. The preliminary tests suggest that the system can allow for 270 determinations per hour, with a linear range from 1.0×10−2 to 1.0×10−4 mol l-1 for the three di¡erent analytes. Detection limits were estimated as 3.1×10−5 , 3.0×10−6 and 1.0×10−5 mol l-1 for Cl-, Ca2+ and K+, respectively. <br> <br> <a target="_blank" href="http://www.hindawi.com/journals/jammc/2002/450969.abs.html"> Texto integral </a> <br> <br>
Abstract (EN): A versatile potentiometer that works with electrode arrays in flow injection and/or monosegmented flow systems is described. The potentiometer is controlled by a microcomputer that allows individual, sequential multiplexed or random accesses to eight electrodes while employing only one reference electrode. The instrument was demonstrated by monitoring an array of seven flow-through ion-selective electrodes for Ag+ and for three electrodes for Cl-, Ca2+ and K+. The figures of merit of the individual and multiplexed (summed) readings of the electrode array were compared. The absolute standard deviation of the measurements made by summing the potential of two or more electrodes was maintained constant, thus improving the precision of the measurements. This result shows that an attempt to combine the signals of the electrodes to produce a more intense signal in the Hadamard strategy is feasible and accompanied by a proportional improvement in the precision of individual measurements. The preliminary tests suggest that the system can allow for 270 determinations per hour, with a linear range from 1.0×10−2 to 1.0×10−4 mol l-1 for the three di¡erent analytes. Detection limits were estimated as 3.1×10−5 , 3.0×10−6 and 1.0×10−5 mol l-1 for Cl-, Ca2+ and K+, respectively. <br> <br> <a target="_blank" href="http://www.hindawi.com/journals/jammc/2002/450969.abs.html"> Full text</a> <br> <br>
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Multicommuted flow system for the determination of glucose in animal blood serum exploiting enzymatic reaction and chemiluminescence detection (2003)
Artigo em Revista Científica Internacional
Pires, CK; Martelli, PB; Reis, BF; Lima, JLFC; Saraiva, MLMFS
Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals (2010)
Artigo em Revista Científica Internacional
Lucia H M L M Santos; Araujo, AN; Boaventura Reis; Montenegro, MCBSM
Design and development of a multichannel potentiometer for monitoring an electrode array and its application in flow analysis (2002)
Artigo em Revista Científica Internacional
Rohwedder, JJR; Pasquini, C; Raimundo, IM; Conceicao, M; Montenegro, BSM; Araujo, AN; Couto, CMCM
An improved leaping detector for flow analysis applied to iron speciation in drugs (2000)
Artigo em Revista Científica Internacional
Santos, SRB; Araujo, MCU; Honorato, RS; Zagatto, EAG; Lima, JLFC; Lapa, RAS
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-08-28 às 15:36:39 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias