Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Determination of Rh, Pd and Pt in urine samples using a pre-concentration sequential injection analysis system coupled to a quadrupole-inductively coupled plasma-mass spectrometer

Publicações

Determination of Rh, Pd and Pt in urine samples using a pre-concentration sequential injection analysis system coupled to a quadrupole-inductively coupled plasma-mass spectrometer

Título
Determination of Rh, Pd and Pt in urine samples using a pre-concentration sequential injection analysis system coupled to a quadrupole-inductively coupled plasma-mass spectrometer
Tipo
Artigo em Revista Científica Internacional
Ano
2007
Autores
Cristina M P V Lopes
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Lucia L M F S Saraiva
(Autor)
FFUP
Revista
Vol. 600 1
Páginas: 226-232
ISSN: 0003-2670
Editora: Elsevier
Indexação
Classificação Científica
CORDIS: Ciências da Saúde
FOS: Ciências exactas e naturais > Química
Outras Informações
ID Authenticus: P-004-7EJ
Resumo (PT): The proposed flow system was developed in order to minimize the drawbacks related to the PGEs determination by quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS). It was intended not only to lower the limits of detection (LODs) but also to eliminate the interferences originating from some atomic and molecular ions produced in the argon plasma. This was accomplished by means of an on-line sample clean-up/pre-concentration step, using a chelating resin (Metalfix™ Chelamine™) in which Rh, Pd and Pt were preferably retained when compared with the interfering species. The results obtained by using the developed flow system in the analysis of urine samples are presented. With a sampling rate of 9 samples h−1 (i.e., 27 determinations) and a sample consumption of ca. 10 mL, the developed flow system allowed linear calibration plots up to 100 ng L−1 with detection limits of 1.2 ng L−1 (Rh), 0.4 ng L−1 (Pd) and 0.9 ng L−1 (Pt). Repeatability studies showed good precision (R.S.D.%, n = 5): 3.7% (Rh); 2.6% (Pd) and 2.4% (Pt), for 10 ng L−1; 2.4% (Rh); 1.4% (Pd) and 1.9% (Pt), for 50 ng L−1; and 1.3% (Rh); 0.58% (Pd) and 0.62% (Pt), for 100 ng L−1. By spiking human urine samples, recovery tests were performed, and the values obtained ranged between 89% and 105% (Rh); 90% and 104% (Pd); and 93% and 105% (Pt). <br> <br> Keywords: Sequential injection analysis flow system; Platinum group elements; Urine; Quadrupole-inductively coupled plasma-mass spectrometry <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TF4-4N61FX1-5&_user=2460038&_coverDate=09%2F26%2F2007&_rdoc=37&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235216%232007%23993999998%23669471%23FLA%23display%23Volume)&_cdi=5216&_sort=d&_docanchor=&_ct=38&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=22226c3a56460d201c490175c51a9b1f"> Texto integral</a> <br> <br>
Abstract (EN): The proposed flow system was developed in order to minimize the drawbacks related to the PGEs determination by quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS). It was intended not only to lower the limits of detection (LODs) but also to eliminate the interferences originating from some atomic and molecular ions produced in the argon plasma. This was accomplished by means of an on-line sample clean -up/pre -concentration step, using a chelating resin (Metalfix (TM) Chelamine (R)) in which Rh, Pd and Pt were preferably retained when compared with the interfering species. The results obtained by using the developed flow system in the analysis of urine samples are presented. With a sampling rate of 9 samples h(-1) (i.e., 27 determinations) and a sample consumption of ca. 10 mL, the developed flow system allowed linear calibration plots up to 100 ngL(-1) with detection limits of 1.2 ngL(-1) (Rh), 0.4 ng L-1 (Pd) and 0.9 ngL(-1) (Pt). Repeatability studies showed good precision (R.S.D.%, n = 5): 3.7% (Rh); 2.6% (Pd) and 2.4% (Pt), for 10 ngL(-1); 2.4% (Rh); 1.4% (Pd) and 1.9% (Pt), for 50 ngL(-1); and 1.3% (Rh); 0.58% (Pd) and 0.62% (Pt), for 100 ngL(-1). By spiking human urine samples, recovery tests were performed, and the values obtained ranged between 89% and 105% (Rh); 90% and 104% (Pd); and 93% and 105% (Pt). (C) 2007 Elsevier B.V All rights reserved.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM

Ver todas (159)

Da mesma revista

Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS (1986)
Outra Publicação em Revista Científica Internacional
ALONSO, J; BARTROLI, J; Lima, JLFC; MACHADO, AASC
Papers presented at the 10th International Conference on Flow Analysis Porto, Portugal, 3-8 September 2006 - Foreword (2007)
Outra Publicação em Revista Científica Internacional
Purnendu Dasgupta; Jose L F C Lima; Lucia Saraiva; Marcela Segundo
Optical probes for detection and quantification of neutrophils' oxidative burst. A review (2009)
Outra Publicação em Revista Científica Internacional
Marisa Freitas; Jose L F C Lima; Eduarda Fernandes
Nanoparticle-based assays in automated flow systems: A review (2015)
Outra Publicação em Revista Científica Internacional
Marieta L C Passos; Paula C A G Pinto; Joao L M Santos; Lucia L M F S Saraiva; Andre R T S Araujo

Ver todas (221)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-08-22 às 14:41:11 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias