Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Flow methodology for methanol determination in biodiesel exploiting membrane-based extraction

Publicações

Flow methodology for methanol determination in biodiesel exploiting membrane-based extraction

Título
Flow methodology for methanol determination in biodiesel exploiting membrane-based extraction
Tipo
Artigo em Revista Científica Internacional
Ano
2008
Autores
Andre R T S Araujo
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Lucia L M F S Saraiva
(Autor)
FFUP
Gracas G A Korn
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 613 1
Páginas: 177-183
ISSN: 0003-2670
Editora: Elsevier
Indexação
Classificação Científica
CORDIS: Ciências da Saúde
FOS: Ciências exactas e naturais > Química
Outras Informações
ID Authenticus: P-004-044
Resumo (PT): A methodology based in flow analysis and membrane-based extraction has been applied to the determination of methanol in biodiesel samples. A hydrophilic membrane was used to perform the liquid–liquid extraction in the system with the organic sample fed to the donor side of the membrane and the methanol transfer to an aqueous acceptor buffer solution. The quantification of the methanol was then achieved in aqueous solution by the combined use of immobilised alcohol oxidase (AOD), soluble peroxidase and 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS). The optimization of parameters such as the type of membrane, the groove volume and configuration of the membrane unit, the appropriate organic solvent, sample injection volume, as well as immobilised packed AOD reactor was performed. Two dynamic analytical working ranges were achieved, up to 0.015% and up to 0.200% (m/m) methanol concentrations, just by changing the volume of acceptor aqueous solution. Detection limits of 0.0002% (m/m) and 0.007% (m/m) methanol were estimated, respectively. The decision limit (CCα) and the detection capacity (CCβ) were 0.206 and 0.211% (m/m), respectively. The developed methodology showed good precision, with a relative standard deviation (R.S.D.) <5.0% (n = 10). Biodiesel samples from different sources were then directly analyzed without any sample pre-treatment. Statistical evaluation showed good compliance, for a 95% confidence level, between the results obtained with the flow system and those furnished by the gas chromatography reference method. The proposed methodology turns out to be more environmental friendly and cost-effective than the reference method. <br> <br> Keywords: Biodiesel; Methanol; Membrane-based extraction; Immobilised enzyme; Flow analysis <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TF4-4S21TPJ-4&_user=2460038&_coverDate=04%2F21%2F2008&_rdoc=9&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235216%232008%23993869997%23684322%23FLA%23display%23Volume)&_cdi=5216&_sort=d&_docanchor=&_ct=14&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=6e0cafd546512af4df204ff5932a1e63"> Texto integrak</a> <br> <br>
Abstract (EN): A methodology based in flow analysis and membrane-based extraction has been applied to the determination of methanol in biodiesel samples. A hydrophilic membrane was used to perform the liquid-liquid extraction in the system with the organic sample fed to the donor side of the membrane and the methanol transfer to an aqueous acceptor buffer solution. The quantification of the methanol was then achieved in aqueous solution by the combined use of immobilised alcohol oxidase (AOD), soluble peroxidase and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS). The optimization of parameters such as the type of membrane, the groove volume and configuration of the membrane unit, the appropriate organic solvent, sample injection volume, as well as immobilised packed AOD reactor was performed. Two dynamic analytical working ranges were achieved, up to 0.015% and up to 0.200% (m/m) methanol concentrations, just by changing the volume of acceptor aqueous solution. Detection limits of 0.0002% (m/m) and 0.007% (m/m) methanol were estimated, respectively The decision limit (CC alpha) and the detection capacity (CC beta) were 0.206 and 0.211% (m/m), respectively The developed methodology showed good precision, with a relative standard deviation (R.S.D.) <5.0% (n = 10). Biodiesel samples from different sources were then directly analyzed without any sample pre-treatment. Statistical evaluation showed good compliance, for a 95% confidence level, between the results obtained with the flow system and those furnished by the gas chromatography reference method. The proposed methodology turns out to be more environmental friendly and cost-effective than the reference method.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 7
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM

Ver todas (159)

Da mesma revista

Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS (1986)
Outra Publicação em Revista Científica Internacional
ALONSO, J; BARTROLI, J; Lima, JLFC; MACHADO, AASC
Papers presented at the 10th International Conference on Flow Analysis Porto, Portugal, 3-8 September 2006 - Foreword (2007)
Outra Publicação em Revista Científica Internacional
Purnendu Dasgupta; Jose L F C Lima; Lucia Saraiva; Marcela Segundo
Optical probes for detection and quantification of neutrophils' oxidative burst. A review (2009)
Outra Publicação em Revista Científica Internacional
Marisa Freitas; Jose L F C Lima; Eduarda Fernandes
Nanoparticle-based assays in automated flow systems: A review (2015)
Outra Publicação em Revista Científica Internacional
Marieta L C Passos; Paula C A G Pinto; Joao L M Santos; Lucia L M F S Saraiva; Andre R T S Araujo

Ver todas (221)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-10-23 às 14:18:49 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico