Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry

Título
Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry
Tipo
Artigo em Revista Científica Internacional
Ano
2021
Autores
Fernandes, SR
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Sa, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Miro, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Marcela A Segundo
(Autor)
FFUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Revista
Vol. 414
Páginas: 649-659
ISSN: 1618-2642
Editora: Springer Nature
Outras Informações
ID Authenticus: P-00V-AAZ
Abstract (EN): An automatic micro-solid-phase extraction (mu SPE) method using on-line renewable sorbent beads followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established for the determination of tranexamic acid (TXA) in urine. The mu SPE method was based on the bead injection (BI) concept combined with the mesofluidic lab-on-valve (LOV) platform. All steps of the mu SPE-BI-LOV were implemented by computer programming, rendering enhanced precision on time and flow events. Several parameters, including the type of sorbent, volume and composition of the conditioning solution, washing solution, and eluent composition, were evaluated to improve the extraction efficiency. The best results were obtained with a hydrophilic-lipophilic balanced mixed-mode sorbent, decorated with sulfonic acid groups (Oasis MCX), and 99% acetonitrile-water (50:50, v/v)-1% ammonium hydroxide as eluent. Chromatographic separation was performed using a BEH amide column coupled to MS/MS detection in positive ionization mode. Good linearity was achieved (R-2 > 0.998) for TXA concentrations in urine ranging from 300 to 3000 ng mL(-1), with LOD and LOQ of 30 and 65 ng mL(-1), respectively. Dilution integrity was observed for dilution factors up to 20,000 times, providing the extension of the upper limit of quantification to 12 mg mL(-1). The method was validated according to international guidelines and successfully applied to urine samples collected during scoliosis surgery of pediatric patients treated with TXA.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 11
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Gold nanoparticles for the development of clinical diagnosis methods (2008)
Outra Publicação em Revista Científica Internacional
Pedro Baptista; Eulalia Pereira; Peter Eaton; Goncalo Doria; Adelaide Miranda; Ines Gomes; Pedro Quaresma; Ricardo Franco
Formation of pyranoanthocyanins in red wines: a new and diverse class of anthocyanin derivatives (2011)
Outra Publicação em Revista Científica Internacional
Victor de Freitas; Nuno Mateus
European analytical column number 50 (2022)
Outra Publicação em Revista Científica Internacional
Razic, S; Marcela A Segundo; Turner, D; Miro, M; Baeumner, AJ
European analytical column number 49 (2021)
Outra Publicação em Revista Científica Internacional
Ra¸i¿, S; Marcela A Segundo; Vogel, M
European analytical column number 48 (2020)
Outra Publicação em Revista Científica Internacional
Razic, S; Marcela A Segundo

Ver todas (70)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-05 às 13:40:25 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias