Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Respiratory movements cause significant misregistration and altered SUVs in thoracic PET-CT studies with 18F-DG

Publicações

Respiratory movements cause significant misregistration and altered SUVs in thoracic PET-CT studies with 18F-DG

Título
Respiratory movements cause significant misregistration and altered SUVs in thoracic PET-CT studies with 18F-DG
Tipo
Artigo em Revista Científica Internacional
Ano
2008
Autores
D. Faria
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
J. Patrina
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
A. Sevilla
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
J. Tavares
(Autor)
FEUP
L. Ribeiro
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
D. Sousa
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
J. Oliveira
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
J. Vale
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
D. C. Costa
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 35
Páginas: S213-S214
ISSN: 1619-7070
Editora: Springer Nature
Indexação
Publicação em ISI Web of Science ISI Web of Science
Classificação Científica
CORDIS: Ciências Tecnológicas > Engenharia
Outras Informações
Abstract (EN): PET-CT with 18F-DG studies are frequently used in the management of patients with lung malignancies. Unfortunately respiratory movements may influence significantly disease evaluation, particularly during longitudinal follow-up. Our aim is to investigate the influence of forced inspiration (I) and expiration (E) on shallow breathing (S) results (anatomic registration and SUV calculation). We included 18 patients, 15 male and 3 female, with ages between 40 and 78 years, with pulmonary and hepatic lesions. Data was acquired on a GE Discovery LS/4 PET-CT Scanner starting 60 to 90 minutes after the i.v. administration of 18F-DG (5 MBq/Kg of patient weight). CT acquisition used 120 kV, 80 mA and 1.5 pitch and PET acquisition on 2D mode included 5 to 6 AFOV (4 minutes per bed position). A further 1 to 2 late AFOV (> 2 hours p.i.) acquisition was routinely undertaken on S and complemented by 2 other attenuation maps with CT, 120 kV, 60 mA and 1.5 pitch, in I and E. PET images (always on S) were acquired in 2D mode, 1 or 2 AFOV/6 minutes. Three emission image sets were then reconstructed with OSEM and MAC using the 3 attenuation maps. Each lung was divided in 3 segments - Superior, Medial and Inferior, and the liver lesions classified in Superior and Deep. Images were then analysed according to lesion anatomic registration, and lesion SUV calculated on I, E and S. Our preliminary results show significant difference between SUV values (p=0.0154) of hepatic lesions located in superior segments in I and E. Lung lesions in the superior segment were better registered in S than in I or E. The worst misregistrations were observed in the inferior segments of the lung, with deviations up to 1,5 cm between I and E. Conclusion: respiratory movements impact significantly in image registration and SUV calculation of lung and hepatic lesions, depending on their regional localization. Failure to correct adequately for respiratory movements in follow-up longitudinal studies may cause significant evaluation errors. A well defined and "rigid" protocol must be used for longitudinal studies.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Contacto: www.fe.up.pt/~tavares
Documentos
Não foi encontrado nenhum documento associado à publicação com acesso permitido.
Publicações Relacionadas

Da mesma revista

PET/MRI technique role in Alzheimer disease (2017)
Artigo em Revista Científica Internacional
Domingos Vieira; Ricardo Vardasca; João Manuel R. S. Tavares
Extraction, selection and comparison of features for an effective automated computer-aided diagnosis of Parkinson's disease based on [123I]FP-CIT SPECT images (2018)
Artigo em Revista Científica Internacional
Francisco P. M. Oliveira; Diogo Borges Faria; Durval C. Costa; Miguel Castelo Branco; João Manuel R. S. Tavares
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-27 às 23:24:16 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico