Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Treatment of male stress urinary incontinence with the adjustable transobturator male system: Outcomes of a multi-center Iberian study

Publicações

Treatment of male stress urinary incontinence with the adjustable transobturator male system: Outcomes of a multi-center Iberian study

Título
Treatment of male stress urinary incontinence with the adjustable transobturator male system: Outcomes of a multi-center Iberian study
Tipo
Artigo em Revista Científica Internacional
Ano
2018
Autores
Angulo, JC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Francisco Cruz
(Autor)
FMUP
Esquinas, C
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Arance, I
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Manso, M
(Autor)
FMUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Rodriguez, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pereira, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ojea, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Carballo, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rabassa, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Teyrouz, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Escribano, G
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Rodriguez, E
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Teba, F
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Celada, G
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Madurga, B
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Alvarez Ossorio, JL
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Marcelino, JP
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Martins, FE
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 37
Páginas: 1458-1466
ISSN: 0733-2467
Editora: Wiley-Blackwell
Outras Informações
ID Authenticus: P-00N-XGX
Abstract (EN): Aim: To evaluate effectiveness and safety of the adjustable transobturator male system (ATOMS) for male stress urinary incontinence (SUI). Material and Methods: A retrospective multicenter study was conducted in nine Iberian institutions using a board-approved database for 215 patients intervened between 2012 and 2017, with no case excluded. Continence status, patient satisfaction, number, and grade of complications (Clavien-Dindo) and factors affecting dry rate at adjustment were evaluated. Multivariate analysis defined the population at best success rate. Incontinence recurrence due to device failure and/or explant was evaluated and Kaplan-Meier curve for durability performed. Results: Adjustment was achieved at a mean 1.4 +/- 1.9 fillings. Dry-rate after adjustment was 80.5% (96.2% mild and 75.3% moderate-severe), 121 (56.3%) used no pads, and 52 (24.2%) a security pad with urine loss under 10 mL. Mean basal daily pad-test and pad-count decreased from 484 +/- 372.3 mL and 3.9 +/- 2 pads to 63.5 +/- 201.2 mL and 0.9 +/- 1.5pads (both P < 0.0001). Satisfaction rate was 85.1% (94.3% mild and 82.1% moderate-severe). Factors associated to dryness were: lesser severity of SUI (P <.0001), absence of radiotherapy (P = 0.0002) and device generation (P = 0.05). Multivariate analysis revealed absence of radiation (OR = 3.12; 1.36-7.19), mild (OR = 19.61; 3.95-100), and moderate (OR = 2.48; 1.1-5.59) SUI were independent predictors. Complications presented in 33(15.35%); 66.7% grade 1, 9.1% grade 2, and 24.2% grade 3. At 24.3 +/- 15 mo mean follow-up device was explanted in seven (3.25%) and SUI worsened after adjustment in nine (4.2%). Dry-rate at follow-up was 73% and durability of device in dry patients at adjustment was 89.8% (82.9-94) at 2-years. Conclusions: This study confirms ATOMS device is safe and achieves high treatment efficacy and patient satisfaction in a multicenter setting. Significantly better results are achieved in less severe and non-irradiated cases. Durability of the device is reassuring in the short-term.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

The urinary and prostatic microbiome in non-neurogenic male LUTS/BPH: A systematic review (2024)
Outra Publicação em Revista Científica Internacional
Pina-Vaz, T; Silva, AC; Silva, C; Miranda, I; Francisco Cruz; Silva, JA
Neurotrophins in Bladder Function: What Do We Know and Where Do We Go From Here? (2014)
Outra Publicação em Revista Científica Internacional
Cruz C.D.
Is the Urothelium Intelligent? (2010)
Outra Publicação em Revista Científica Internacional
Birder, LA; Kanai, AJ; Francisco Cruz; Moore, K; Fry, CH
Is it Possible to Regenerate the Underactive Detrusor? Part 2 Electrical Stimulation Therapies, Treatment of Bladder Outlet Obstruction, Constipation, and Pelvic Floor Disorders ICI-RS 2024 (2024)
Outra Publicação em Revista Científica Internacional
Sinha, S; Gajewski, JB; Tarcan, T; Van Huele, A; Francisco Cruz; Martinez, EM; Przydacz, M; Kheir, GB; Lombardo, R; Wein, A; Abrams, P

Ver todas (26)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-15 às 18:34:27 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico