Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > A European Multicenter Study of 616 Patients Receiving the Freedom Solo Stentless Bioprosthesis

Publicações

A European Multicenter Study of 616 Patients Receiving the Freedom Solo Stentless Bioprosthesis

Título
A European Multicenter Study of 616 Patients Receiving the Freedom Solo Stentless Bioprosthesis
Tipo
Artigo em Revista Científica Internacional
Ano
2016
Autores
Thalmann, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Grubitzsch, H
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Matschke, K
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Glauber, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Tan, E
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Francois, K
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Hensens, AG
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Cesari, F
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Feyrer, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Diegeler, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Veit, F
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Repossini, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
A Revista está pendente de validação pelos Serviços Administrativos.
Vol. 101
Páginas: 100-109
ISSN: 0003-4975
Outras Informações
ID Authenticus: P-00K-08R
Abstract (EN): Background. The purpose of this study was to evaluate the safety and performance of the Freedom Solo valve in aortic valve replacement by clinical and hemodynamic outcomes. Methods. Six hundred sixteen patients underwent aortic valve replacement in 18 European centers; mean age was 74.5 +/- 5.9 years, 54.1% of the patients were male, and concomitant procedures were performed in 43.2% of the patients. The majority (69%) of the implanted sizes were 23 mm and 25 mm. Results. At 1 year, overall survival was 94.0%, whereas freedom from valve-related death was 98.6%. There were 9 (1.5%) early (<= 30 days) and 27 (4.4%) late (>30 days) deaths. Early and late valve-related mortality was 0.3% (n = 2) and 1.1% (n = 7), respectively. Freedom from explant was 97.6%; 10 valves were explanted for endocarditis and 4 for paravalvular leak. There were 10 (1.6%) early and 5 (0.8%) late strokes. Atrioventricular block requiring pacemaker implant occurred in 8 (1.3%) and 1 (0.2%) patients in the early and late postoperative period, respectively. Thrombocytopenia was seen in 27 cases (4.4%) in the early postoperative period. Preoperatively, 93.8% of patients were in New York Heart Association functional classes II through IV, whereas at 1 year 96.9% of patients were in New York Heart Association functional classes I and II. At 1-year follow-up, mean and peak pressure gradients were 7.2 and 14.6 mm Hg, respectively. Indexed left ventricular mass decreased by 12% from 138 g/m(2) at discharge to 122 g/m(2) at 1 year. Conclusions. At 1-year follow-up after Freedom Solo implantation, we found acceptable clinical results with low mortality and morbidity and good hemodynamic performance, confirming safety and effectiveness in this multicenter experience. (C) 2016 by The Society of Thoracic Surgeons
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 10
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Giant Nondissecting Ascending Aortic Aneurysm in a Paucisymptomatic Young Man (2019)
Outra Publicação em Revista Científica Internacional
Quina Rodrigues, C; Marinho, B; Pissarra, D; Bettencourt, N; Gaspar, A; Almeida, J; Rodrigues Sousa, A
PaO2/FiO(2) Deterioration During Stable Extracorporeal Membrane Oxygenation Associates With Protracted Recovery and Increased Mortality in Severe Acute Respiratory Distress Syndrome (2016)
Artigo em Revista Científica Internacional
Roncon-Albuquerque R Jr; Ferreira Coimbra, J; Vilares Morgado, R; Araújo JP; Paiva, J-A
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-10-18 às 00:40:38 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico