Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Freedom Solo (R) versus Trifecta (R) bioprostheses: clinical and haemodynamic evaluation after propensity score matching

Publicações

Freedom Solo (R) versus Trifecta (R) bioprostheses: clinical and haemodynamic evaluation after propensity score matching

Título
Freedom Solo (R) versus Trifecta (R) bioprostheses: clinical and haemodynamic evaluation after propensity score matching
Tipo
Artigo em Revista Científica Internacional
Ano
2018
Autores
Raimundo, R
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Moreira, S
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Saraiva, FA
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Andrade, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Salgueiro, E
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pinho, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Leite-Moreira AF
(Autor)
FMUP
Revista
Vol. 53
Páginas: 1264-1271
ISSN: 1010-7940
Editora: Elsevier
Outras Informações
ID Authenticus: P-00R-AAQ
Abstract (EN): OBJECTIVES: The goal of this study was to compare the stentless Freedom Solo (R) (FS) and the stented Trifecta (R) (TF) aortic bioprostheses with regard to haemodynamic profile, left ventricular mass regression and early and late postoperative outcomes and survival. METHODS: A longitudinal cohort study of consecutive patients undergoing aortic valve replacement (2009-16) with either the FS or TF at 1 centre was performed. Local databases and national records were queried. Prosthesis haemodynamics and left ventricular dimensions were obtained from postoperative echocardiograms. After propensity score matching (21 covariates), the Kaplan-Meier and competing risk analyses were performed for survival and the combined outcome of structural valve deterioration and endocarditis, respectively. Haemodynamics and mass regression were assessed by a mixed-effects model including propensity score as a covariate. RESULTS: From a total sample of 397 patients with the FS and 525 TF bioprostheses with a median follow-up time of 4.0 (2.2-6.0) and 2.4 (1.4-3.7) years, respectively, a matched sample of 329 pairs was obtained. Matched groups showed no differences in survival (hazard ratio = 1.04, 95% confidence interval = 0.69-1.56) or cumulative hazards of combined outcome (subdistribution hazard ratio = 0.54, 95% confidence interval = 0.21-1.39). Although the TF showed an improved haemodynamic profile, no difference was found in mass regression. Patients with TF bioprostheses had higher rates of prolonged mechanical ventilation, whereas patients with the FS bioprosthesis showed higher rates of thrombocytopenia. CONCLUSIONS: The TF showed an improved haemodynamic profile compared to the FS, but this did not translate into further reverse remodelling. Postoperative outcomes and survival rates were comparable for both bioprostheses. Long-term follow-up is needed for comparisons with classical bioprosthesis models.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 8
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Surgical treatment of atrial fibrillation: an updated review (2014)
Outra Publicação em Revista Científica Internacional
Pinho Gomes, AC; Amorim MJ; Oliveira SM; Leite-Moreira AF
Severe degenerative prolapse hiding a double-orifice mitral valve (2013)
Outra Publicação em Revista Científica Internacional
Almeida, J; Paiva, M; Ferreira, J; Amorim MJ
Reply to Ngu et al. (2018)
Outra Publicação em Revista Científica Internacional
Cerqueira, RJ; Amorim MJ; Andre P Lourenco; Leite-Moreira AF
Permanent pacemaker requirement after concomitant surgical ablation for atrial fibrillation Reply (2014)
Outra Publicação em Revista Científica Internacional
Pinho Gomes, AC; Oliveira SM; Amorim MJ; Leite-Moreira AF
Contemporary results after surgical repair of type A aortic dissection in patients aged 80 years and older: a systematic review and meta-analysis (2011)
Outra Publicação em Revista Científica Internacional
Biancari, F; Vasques, F; Benenati, V; Juvonen, T

Ver todas (12)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-04 às 16:03:35 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias