Three-dimensional proximal flow convergence automatic calculation for determining mitral valve area in rheumatic mitral stenosis

Título
Three-dimensional proximal flow convergence automatic calculation for determining mitral valve area in rheumatic mitral stenosis
Tipo
Artigo em Revista Científica Internacional
Ano
2017
Autores
Sampaio, F
(Autor)
FMUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Ladeiras-Lopes R
(Autor)
FMUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Almeida, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Fonseca, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Fontes-Carvalho R
(Autor)
FMUP
Ribeiro, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Gama, V
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Título: EchocardiographyImportada do Authenticus Pesquisar Publicações da Revista
Vol. 34
Páginas: 1002-1009
ISSN: 0742-2822
Editora: Wiley-Blackwell
Outras Informações
ID Authenticus: P-00R-AQY
Abstract (EN): Purpose: Management of patients with mitral stenosis (MS) depends heavily on the accurate quantification of mitral valve area (MVA) using echocardiography. All currently used two-dimensional (2D) methods have limitations. Estimation of MVA using the proximal isovelocity surface area (PISA) method with real time three-dimensional (3D) echocardiography may circumvent those limitations. We aimed to evaluate the accuracy of 3D direct measurement of PISA in the estimation of MVA. Methods: Twenty-seven consecutive patients (median age of 63 years; 77.8% females) with rheumatic MS were prospectively studied. Transthoracic and transesophageal echocardiography with 2D and 3D acquisitions were performed on the same day. The reference method for MVA quantification was valve planimetry after 3D-volume multiplanar reconstruction. A semi-automated software was used to calculate the 3D flow convergence volume. Results: Compared to MVA estimation using 3D planimetry, 3D PISA showed the best correlation (rho=0.78, P<.0001), followed by pressure half-time (PHT: rho=0.66, P<.001), continuity equation (CE: rho=0.61, P=.003), and 2D PISA (rho=0.26, P=.203). Bland-Altman analysis revealed a good agreement for MVA estimation with 3D PISA (mean difference -0.03 cm(2); limits of agreement (LOA) -0.40-0.35), in contrast to wider LOA for 2D methods: CE (mean difference 0.02 cm(2), LOA -0.56-0.60); PHT (mean difference 0.31 cm(2), LOA -0.32-0.95); 2D PISA (mean difference -0.03 cm(2), LOA -0.92-0.86). Conclusions: MVA estimation using 3D PISA was feasible and more accurate than 2D methods. Its introduction in daily clinical practice seems possible and may overcome technical limitations of 2D methods.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 8
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Thoracic Aortic Thrombus Due to Paradoxical Embolism in a Patient with a Small Patent Foramen Ovale (2009)
Outra Publicação em Revista Científica Internacional
Ricardo Lopes; Nuno P Oliveira; Filipe Macedo; Maria J Maciel
Left-side pericardial agenesis: Putting the pieces together (2018)
Outra Publicação em Revista Científica Internacional
Ruivo, C; Ladeiras-Lopes R; Faria, R; Ferreira, N; Gama, V
A rare case series of mitral valve clefts diagnosed by 3D echocardiography and mini-review of the literature (2019)
Outra Publicação em Revista Científica Internacional
Moura Ferreira, S; Sampaio, F; Ribeiro, J; Fontes-Carvalho R
Thoracic aortic thrombus due to paradoxical embolism in a patient with a small patent foramen ovale (2009)
Artigo em Revista Científica Internacional
Lopes R; Oliveira NP; Macedo F; Maciel MJ
Spirito-Maron Echocardiographic Score: A Marker for Morphological and Physiological Assessment of Patients with Hypertrophic Cardiomyopathy (2014)
Artigo em Revista Científica Internacional
Rangel, I; Goncalves, A; de Sousa, C; Correia, AS; Pinho, T; Madureira, AJ; Martins, E; Silva Cardoso, J; Filipe Macedo; Maciel MJ

Ver todas (9)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-08-20 às 04:39:10 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias