Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams

Publicações

Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams

Título
Monte Carlo calculation of quality correction factors based on air kerma and absorbed dose to water in medium energy x-ray beams
Tipo
Artigo em Revista Científica Internacional
Ano
2020
Autores
Czarnecki, D
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Zink, K
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pimpinella, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Borbinha, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Teles, P
(Autor)
FCUP
Pinto, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 65
ISSN: 0031-9155
Outras Informações
ID Authenticus: P-00T-9H4
Abstract (EN): Clinical dosimetry is typically performed using ion chambers calibrated in terms of absorbed dose to water. As primary measurement standards for this quantity for low and medium energy x-rays are available only since a few years, most dosimetry protocols for this photon energy range are still based on air kerma calibration. For that reason, data for beam quality correction factors k(Q,Q0), necessary for the application of dose to water based protocols, are scarce in literature. Currently the international IAEA TRS-398 Code of Practice is under revision and new k(Q,Q0) factors for a large number of ion chambers will be introduced in the update of this protocol. Several international groups provided the IAEA with experimental and Monte Carlo based data for this revision. Within the European Community the EURAMET 16NRM03 RTNORM project was initiated for that purpose. In the present study, Monte Carlo based results for the beam quality correction factors in medium energy x-ray beams for six ion chambers applying different Monte Carlo codes are presented. Additionally, the perturbation factor p(Q), necessary for the calculation of dose to water from an air kerma calibration coefficient, was determined. The beam quality correction factor k(Q,Q0) for the chambers varied in the investigated energy range by about 4%-5%, and for five out of six chambers the data could be fitted by a simple logarithmic function, if the half-value-layer was used as the beam quality specifier. Corresponding data using different Monte Carlo codes for the same ion chamber agreed within 0.5%. For the perturbation factor p(Q), the data did not obey a comparable simple relationship with the beam quality specifier. The variation of p(Q) for all ion chambers was in the range of 3%-4%. Compared to recently published data, our p(Q) data is around 1% larger, although the same Monte Carlo code has been used. Compared to the latest experimental data, there are even deviations in the range of 2%.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 14
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Medical staff extremity dosimetry in CT fluoroscopy: an anthropomorphic hand voxel phantom study (2013)
Artigo em Revista Científica Internacional
Figueira, C; Becker, F; Blunck, C; DiMaria, S; Baptista, M; Esteves, B; Paulo, G; Santos, J; Teles, P; Vaz, P
Determination of consensus k(Q) values for megavoltage photon beams for the update of IAEA TRS-398 (2020)
Artigo em Revista Científica Internacional
Andreo, P; Burns, DT; Kapsch, RP; McEwen, M; Vatnitsky, S; Andersen, CE; Ballester, F; Borbinha, J; Delaunay, F; Francescon, P; Hanlon, MD; Mirzakhanian, L; Muir, B; Ojala, J; Oliver, CP; Pimpinella, M; Pinto, M; de Prez, LA; Seuntjens, J; Sommier, L...(mais 4 autores)
Calculated beam quality correction factors for ionization chambers in MV photon beams (2020)
Artigo em Revista Científica Internacional
Tikkanen, J; Zink, K; Pimpinella, M; Teles, P; Borbinha, J; Ojala, J; Siiskonen, T; Goma, C; Pinto, M
A System for Digital Processing of Ophthalmic Images (1994)
Artigo em Revista Científica Internacional
Ana Maria Mendonça; Aurélio Campilho; José R. Nunes
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-16 às 13:25:39 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias