Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry

Publicações

Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry

Título
Non-invasive assessment of cerebral oxygenation: A comparison of retinal and transcranial oximetry
Tipo
Artigo em Revista Científica Internacional
Ano
2018
Autores
Van Keer, K
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Van Keer, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Breda, JB
(Autor)
FMUP
Nassiri, V
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
De Deyne, C
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Genbrugge, C
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pinto, LA
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Stalmans, I
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Vandewalle, E
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Título: PLoS ONEImportada do Authenticus Pesquisar Publicações da Revista
Vol. 13 1
ISSN: 1932-6203
Outras Informações
ID Authenticus: P-00N-FZ5
Resumo (PT):
Abstract (EN): Background To investigate the correlation between cerebral (SO2-transcranial), retinal arterial (SaO(2-retinal)) and venous (SvO(2-retinal)) oxygen saturation as measured by near-infrared spectroscopy (NIRS) and retinal oximetry respectively. Methods Paired retinal and cerebral oxygen saturation measurements were performed in healthy volunteers. Arterial and venous retinal oxygen saturation and diameter were measured using a non-invasive spectrophotometric retinal oximeter. Cerebral oxygen saturation was measured using near-infrared spectroscopy. Correlations between SO2-transcranial and retinal oxygen saturation and diameter measurements were assessed using Pearson correlation coefficients. Lin's concordance correlation coefficient (CCC) and Bland-Altman analysis were performed to evaluate the agreement between SO2-transcranial as measured by NIRS and as estimated using a fixed arterial: venous ratio as 0.3 x SaO(2-retinal) + 0.7 x SvO(2-retinal). The individual relative weight of SaO(2-retinal) and SvO(2-retinal) to obtain the measured SO2-transcranial was calculated for all subjects. Results Twenty-one healthy individuals aged 26.4 +/- 2.2 years were analyzed. SO2-transcranial was positively correlated with both SaO(2-retinal) and SvO(2-retinal) (r = 0.44, p = 0.045 and r = 0.43, p = 0.049 respectively) and negatively correlated with retinal venous diameter (r = -0.51, p = 0.017). Estimated SO2-transcranial based on retinal oximetry showed a tolerance interval of (-13.70 to 14.72) and CCC of 0.46 (95% confidence interval: 0.05 to 0.73) with measured SO2-transcranial. The average relative weights of SaO(2-retinal) and SvO(2-retinal) to obtain SO2-transcranial were 0.31 +/- 0.11 and 0.69 +/- 0.11, respectively. Conclusion This is the first study to show the correlation between retinal and cerebral oxygen saturation, measured by NIRS and retinal oximetry. The average relative weight of arterial and venous retinal oxygen saturation to obtain the measured transcranial oxygen saturation as measured by NIRS, approximates the established arterial: venous ratio of 30:70 closely, but shows substantial inter-individual variation. These findings provide a proof of concept for the role of retinal oximetry in evaluating cerebral oxygenation.
Idioma: Inglês
Tipo (Avaliação Docente): Divulgação
Nº de páginas: 14
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Reliability in long-term clinical studies of disease-modifying therapies for relapsing-remitting multiple sclerosis: A systematic review (2020)
Outra Publicação em Revista Científica Internacional
Lucchetta, RC; Leonart, LP; Goncalves, MVM; Becker, J; Pontarolo, R; Fernandez Llimos, F; Wiens, A
Questionnaires measuring movement behaviours in adults and older adults: Content description and measurement properties. A systematic review (2022)
Outra Publicação em Revista Científica Internacional
Rodrigues, B; Encantado, J; Carraca, E; Sousa Sa, E; Lopes, L; Cliff, D; Mendes, R; Silva, MN; Godinho, C; Santos, R
Mapping the characteristics of network meta-analyses on drug therapy: A systematic review (2018)
Outra Publicação em Revista Científica Internacional
Tonin, FS; Steimbach, LM; Mendes, AM; Borba, HH; Pontarolo, R; Fernandez Llimos, F
Fecal microbiota transplantation in inflammatory bowel disease patients: A systematic review and meta-analysis (2020)
Outra Publicação em Revista Científica Internacional
Caldeira, LD; Borba, HH; Tonin, FS; Wiens, A; Fernandez Llimos, F; Pontarolo, R
Establishing the criterion validity of self-report measures of adherence in hemodialysis through associations with clinical biomarkers: A systematic review and meta-analysis (2022)
Outra Publicação em Revista Científica Internacional
Sousa, H; Ribeiro, O; Costa, E; Christensen, AJ; Figueiredo, D

Ver todas (436)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-08-22 às 04:14:36 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias