Quantification of the difference between Cardiac Magnetic Resonance signals in perfusion studies with and without motion correction algorithms

Título
Quantification of the difference between Cardiac Magnetic Resonance signals in perfusion studies with and without motion correction algorithms
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2019
Autores
Moreira, T
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Almeida, N
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Bettencourt, N
(Autor)
FMUP
Coimbra, M
(Autor)
FCUP
Ata de Conferência Internacional
6th IEEE Portuguese Meeting on Bioengineering, ENBENG 2019
22 February 2019 through 23 February 2019
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-00Q-K0D
Abstract (EN): In studies requiring respiratory apnea, such as the cardiac magnetic resonance (CMR) perfusion sequence, it is sometimes difficult for patients to perform such a requirement. In the medical imaging market, motion correction algorithms have emerged, such as motion correction (MoCo) from Siemens, as computational tools capable of correcting this dilemma. It is important to verify, by the signal intensity of the images, if the images of the sequences with the application of the algorithm do not differ significantly from the images without any post-processing. An experimental study was carried out to measure signal intensity by region of interest (ROI) marking, one of which was located in the cardiac chamber and another in the segment with ischemia in thirteen individuals (n = 13) with a diagnosis of ischemia of the anterior descendent artery who performed the perfusion sequence by CMR. Statistical analysis with the values resulting from these measurements was performed using the statistical analysis software IBM SPSS Statistics 24. Signal strength measurements were performed at the Alfena Private Hospital with Siemens Syngo MR D14 software. It is verified that there are no statistically significant differences in the signal intensity measurements in the images without and with the motion correction algorithm.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 4
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-31 às 13:26:45 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias