Computer analysis of maternal-fetal heart rate recordings during labor in relation with maternal-fetal attachment and prediction of newborn acidemia

Título
Computer analysis of maternal-fetal heart rate recordings during labor in relation with maternal-fetal attachment and prediction of newborn acidemia
Tipo
Artigo em Revista Científica Internacional
Ano
2016
Revista
Vol. 29
Páginas: 1440-1444
ISSN: 1476-7058
Editora: Taylor & Francis
Outras Informações
ID Authenticus: P-00K-6KG
Abstract (EN): Objective: To assess combined maternal (MHR) and fetal heart rate (FHR) recordings during labor, in relation with maternal-fetal attachment and prediction of newborn acidemia.Study design: Fifty-nine simultaneous MHR and FHR recordings were acquired in the final minutes of labor. Computer analysis followed the FIGO guidelines with estimation of MHR and FHR baselines, accelerations, decelerations, short- (STV) and long-term variabilities. MHR and FHR characteristics, their differences and correlations were assessed in relation to labor progression and to newborn umbilical artery blood (UAB) pH lower than 7.15 and 7.20. To assess prediction of acidemia, areas under ROC curves (auROC) were calculated.Results: Progression of labor was associated with a significant increase in MHR accelerations and FHR decelerations both in the non-acidemic and acidemic fetuses (p<0.01). At the same time there was an increase in MHR-FHR correlations and differences in accelerations and decelerations in acidemic fetuses. The auROC ranged between 0.50 for FHR accelerations and 0.77 for MHR baseline plus FHR STV.Conclusions: MHR and FHR respond differently during labor with signs of increased maternal-fetal attachment during labor progression in acidemic fetuses. Combined MHR-FHR analysis may help to improve prediction of newborn acidemia compared with FHR analysis alone.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 5
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Dos mesmos autores

Improvements in fetal heart rate analysis by the removal of maternal-fetal heart rate ambiguities (2015)
Artigo em Revista Científica Internacional
Pinto, P; Cristina Costa Santos; Hernani Goncalves; Diogo Ayres de Campos; Joao Bernardes

Da mesma revista

Risk of hemorrhage in abnormally invasive placenta according to its management (2017)
Outra Publicação em Revista Científica Internacional
Pinto, PV; Machado, AP; Montenegro, N
Rights of the newborn and end-of-life decisions (2012)
Outra Publicação em Revista Científica Internacional
Guimarães H; Rocha, G; Bellieni, C; Buonocore, G
Present and future of European neonatology Focus on Patent Ductus Arteriosus (2009)
Outra Publicação em Revista Científica Internacional
Fanos, V; Guimarães H
Neonatal hepatobiliar disease (2012)
Outra Publicação em Revista Científica Internacional
Guimarães H; Rocha, G; Pissarra, S

Ver todas (32)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-23 às 03:57:50 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias