Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Analysing the peripheral nerve tissue using distinct discretization techniques

Publicações

Analysing the peripheral nerve tissue using distinct discretization techniques

Título
Analysing the peripheral nerve tissue using distinct discretization techniques
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2019
Autores
T. M. Albuquerque
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Jorge Belinha
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Renato Natal Jorge
(Autor)
FEUP
Ata de Conferência Internacional
Páginas: 1-4
6th IEEE Portuguese Meeting on Bioengineering, ENBENG 2019
22 February 2019 through 23 February 2019
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-00Q-K0Q
Abstract (EN): The main purpose of this work is to study the biomechanical behaviour of a peripheral nerve tissue when submitted to mechanical stretching forces. Nerve injury reduces life quality and has a strong impact on the national productivity, so it is essential to study the biomechanical properties of peripheral nerves to improve the repair and regeneration procedure. The study was conducted on a 2D and a 3D model of a sciatic nerve bifurcation in the lower thigh. These models were inspired on a real nerve bifurcation and have been developed using several computational tools. It was used the finite element method (FEM), Radial Point Interpolation Method (RPIM) and Neighbour Radial Point Interpolation Method (NNRPIM) to perform the analyses in FEMAS (R). The results of the analysis with the three different methods are very similar, the main stress is observed always in the same region in both 2D and 3D models and the displacement results for the selected points in the two models are concordant. The results obtained by the three different analysis methods are very similar which not only allow to conclude that these methods are appropriate numerical tools to analyse the biomechanical behaviour of peripheral nerve tissue but also confirms the robustness of the used methods.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 4
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-29 às 19:28:13 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico