Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Extraction, selection and comparison of features for an effective automated computer-aided diagnosis of Parkinson's disease based on [123I]FP-CIT SPECT images

Publicações

Extraction, selection and comparison of features for an effective automated computer-aided diagnosis of Parkinson's disease based on [123I]FP-CIT SPECT images

Título
Extraction, selection and comparison of features for an effective automated computer-aided diagnosis of Parkinson's disease based on [123I]FP-CIT SPECT images
Tipo
Artigo em Revista Científica Internacional
Ano
2018-06
Autores
Francisco P. M. Oliveira
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Diogo Borges Faria
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Durval C. Costa
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Miguel Castelo Branco
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
João Manuel R. S. Tavares
(Autor)
FEUP
Revista
Vol. 45 6
Páginas: 1052-1062
ISSN: 1619-7070
Editora: Springer Nature
Indexação
Classificação Científica
CORDIS: Ciências Tecnológicas
FOS: Ciências médicas e da saúde
Outras Informações
ID Authenticus: P-00N-BQ9
Resumo (PT):
Abstract (EN): Purpose This work aimed to assess the potential of a set of features extracted from [I-123] FP-CIT SPECT brain images to be used in the computer-aided "in vivo" confirmation of dopaminergic degeneration and therefore to assist clinical decision to diagnose Parkinson's disease. Methods Seven features were computed from each brain hemisphere: five standard features related to uptake ratios on the striatum and two features related to the estimated volume and length of the striatal region with normal uptake. The features were tested on a dataset of 652 [I-123] FP-CIT SPECT brain images from the Parkinson's Progression Markers Initiative. The discrimination capacities of each feature individually and groups of features were assessed using three different machine learning techniques: support vector machines (SVM), k-nearest neighbors and logistic regression. Results Cross-validation results based on SVM have shown that, individually, the features that generated the highest accuracies were the length of the striatal region (96.5%), the putaminal binding potential (95.4%) and the striatal binding potential (93.9%) with no statistically significant differences among them. The highest classification accuracy was obtained using all features simultaneously (accuracy 97.9%, sensitivity 98% and specificity 97.6%). Generally, slightly better results were obtained using the SVM with no statistically significant difference to the other classifiers for most of the features. Conclusions The length of the striatal region uptake is clinically useful and highly valuable to confirm dopaminergic degeneration "in vivo" as an aid to the diagnosis of Parkinson's disease. It compares fairly well to the standard uptake ratio-based features, reaching, at least, similar accuracies and is easier to obtain automatically. Thus, we propose its day to day clinical use, jointly with the uptake ratio-based features, in the computer-aided diagnosis of dopaminergic degeneration in Parkinson's disease.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 11
Documentos
Nome do Ficheiro Descrição Tamanho
EJNM-D-17-00701 Paper draft 1191.32 KB
paper 1st page 376.02 KB
Publicações Relacionadas

Das mesmas áreas científicas

Dispositivo para medir força e energia musculares (2015)
Patente
Manuel Rodrigues Quintas; Maria Teresa Restivo; Bruno Santos; Carlos Moreira Da Silva; Tiago Faustino Andrade
Device for measuring skinfold thickness (2015)
Patente
Manuel Rodrigues Quintas; Carlos Moreira da Silva; Tiago Faustino Andrade; Maria Teresa Restivo; Maria de Fátima Chouzal; Amaral, Teresa
Voriconazole loaded chitosan nanoparticles as novel drug delivery system for the localized management of bone infection (2024)
Poster em Conferência Internacional
Ferraz, MP; Miguel Zegre; Joana Barros; Ana Bettencourt; Lídia Caetano; Liliana Gonçalves; B. David
Flavonoids and Omega-3 fatty acid-loaded lipid nanocarriers as promising antimicrobial biofilm strategies (2024)
Poster em Conferência Internacional
Ferraz, MP; Ana Beatriz Pereira; Mariana Terroso; Carla Martins Lopes; Marlene Lúcio
Chlorhexidine-releasing composite hydrogel for the prevention and control of bacterial infections (2023)
Poster em Conferência Internacional
Ferraz, MP; Barros, J; Liliana Grenho; Fernandes, A.L.

Ver todas (187)

Da mesma revista

Respiratory movements cause significant misregistration and altered SUVs in thoracic PET-CT studies with 18F-DG (2008)
Artigo em Revista Científica Internacional
D. Faria; J. Patrina; A. Sevilla; J. Tavares; L. Ribeiro; D. Sousa; J. Oliveira; J. Vale; D. C. Costa
PET/MRI technique role in Alzheimer disease (2017)
Artigo em Revista Científica Internacional
Domingos Vieira; Ricardo Vardasca; João Manuel R. S. Tavares
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z