Abstract (EN):
This paper presents an orthogonal implementation for power system state estimators based on the Maximum Correntropy Criterion (MCC). The proposed approach leads to a numerically robust estimator which exhibits self -healing properties, in the sense that gross errors in analog measurements are automatically rejected. As a consequence, robust estimates are produced without the need of running the state estimator again after bad data identification and removal. Numerical robustness is achieved by means of a specialized orthogonal algorithm based on fast Givens Rotations, which is able to handle the dynamic measurement weighting mechanism implied by the Parzen window concept associated to MCC. Results for a 3 -bus test system are presented to properly illustrate the Correntropy principles, and several case studies conducted on the IEEE 30 -bus and 57 -bus benchmark systems are used to validate the proposed methodology.
Idioma:
Inglês
Tipo (Avaliação Docente):
Científica
Nº de páginas:
6