Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > ADIPSMETER A New Skinfold Calliper System

Publicações

ADIPSMETER A New Skinfold Calliper System

Título
ADIPSMETER A New Skinfold Calliper System
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2011
Autores
Maria de Fátima Chouzal
(Autor)
FEUP
Manuel Rodrigues Quintas
(Autor)
FEUP
da Silva, CM
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ata de Conferência Internacional
Páginas: 174-178
International Conference on Biomedical Electronics and Devices, BIODEVICES 2011
Rome, 26 January 2011 through 29 January 2011
Outras Informações
ID Authenticus: P-002-W36
Abstract (EN): Nowadays, the assessment of body composition is of great meaning but traditional skinfold callipers recognized in the nutritional area have not been technologically updated to provide a more effective performance with greater accuracy, allowing automatic data processing and recording in a database, offering a more user friendly handling not requiring technicians with a high degree of expertise. In order to overcome many of these deficiencies a new instrument named Adipsmeter was designed and developed. A new mechanical skinfold calliper structure has been digitally instrumented for reading skinfold thickness and equipped with wireless communication capabilities with a personal computer where a software application, integrating a database, is installed and prepared for driving a technician along a specific protocol incorporating many regression equations used in current body fat measurement at an affordable price. Its measurement range is from 0 to 110 mm, consistent with a range of use from children to obese individuals. Between the two opposing clamping surfaces mounted on its rigid arms the pressure has a constant value of 10 gf/mm(2) in the whole measurement range. It has small dimension and weight and while being robust provides comfortable handling. The sensing system resolution is less than 0.1 mm, the wireless communication (MiWi) is suitable for healthcare environments, with 25 h of autonomy. The software application, with an intuitive and user friendly interface, is based in Visual Basic 2008.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 5
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-08-30 às 18:31:35 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias