Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters

Publicações

Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters

Título
Fast and sensitive UHPLC methods with fluorescence and tandem mass spectrometry detection for the determination of tetracycline antibiotics in surface waters
Tipo
Artigo em Revista Científica Internacional
Ano
2013
Autores
Karolina Skraskova
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Lucia H M L M Santos
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Dalibor Satinsky
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Angelina Pena
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Maria Conceicao B S M Montenegro
(Autor)
FFUP
Petr Solich
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Lucie Novakova
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 927
Páginas: 201-208
ISSN: 1570-0232
Editora: Elsevier
Classificação Científica
FOS: Ciências exactas e naturais > Química
Outras Informações
ID Authenticus: P-005-0QK
Abstract (EN): In this paper two fast and highly sensitive ultra-high performance liquid chromatography (UHPLC) methods for the determination of tetracycline antibiotics (oxytetracycline, tetracycline, doxycycline, demeclocycline, chlortetracycline, minocycline and degradation product epitetracycline) in surface waters have been developed using fluorescence (FL) and mass spectrometry (MS) detection. ACQUITY UPLC BEH C8 and ACQUITY CSH C18 columns were employed for FL and MS detection, respectively, both packed with 1.7 mu m particles. Mixed-mode separation mechanism of CSH (charged surface technology) sorbent was found particularly useful in analysis of TCs, which possess problematic amphoteric structures. The FL methodology was based on chelation of tetracyclines with calcium ions to perform on-column derivatisation. The developed methods were compared in the terms of validation parameters including linearity, sensitivity, precision and accuracy. The linearity range for FL detection was within 7 ng mL(-1) to 50 mu g mL(-1) with method limit of detection (MLOD) as low as 0.2 ng mL(-1) for most of the analytes. MS detection showed even higher sensitivity reaching MLOD of 0.003 ngmL(-1), which is the highest sensitivity reported so far in analysis of TCs. Matrix matched calibration curves in the range of 0.01-50 ng mL(-1) were used for quantification to compensate for matrix effects with the correlation coefficients demonstrating good linearity (0.9940-0.9999). The extraction of the antibiotics from surface waters was performed using solid phase extraction with Oasis HLB cartridges. Accuracy was expressed as recovery with values ranging from 96.52% to 127.30% and from 91.66% to 123.70% for FL and MS detection, respectively.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 8
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

The relationship between Candida species charge density and chitosan activity evaluated by ion-exchange chromatography (2011)
Artigo em Revista Científica Internacional
Palmeira de Oliveira, A; Passarinha, LA; Gaspar, C; Palmeira de Oliveira, R; Sarmento, B; Martinez de Oliveira, J; pina-vaz, c; rodrigues, ag; Queiroz, JA
Separation of human immunoglobulin G subclasses on a protein A monolith column (2014)
Artigo em Revista Científica Internacional
Pelin Leblebici ; M. Enis Leblebici; Frederico Ferreira da Silva; Alírio E. Rodrigues; Luís S. Pais
Sample preparation and chromatographic methods for the determination of protein-bound uremic retention solutes in human biological samples: An overview (2023)
Artigo em Revista Científica Internacional
Fernandes, SR; Meireles, AN; Marques, SS; Silva, L; Luisa Barreiros; Benedita Sampaio-Maia; Miro, M; Marcela A Segundo
Quantification of doping compounds in faecal samples from racing pigeons, by liquid chromatography-tandem mass spectrometry (2018)
Artigo em Revista Científica Internacional
Moreira, FX; Silva, R; Andre, MB; de Pinho, PG; Maria de Lourdes Bastos; Ruivo, J; Ruivo, P; Helena Carmo
Quantification of alpha-amanitin in biological samples by HPLC using simultaneous UV- diode array and electrochemical detection (2015)
Artigo em Revista Científica Internacional
Juliana Garcia; Vera M Costa; Paula Baptista; Maria de Lourdes Bastos; Felix Carvalho

Ver todas (17)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-24 às 05:02:16 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico