Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Dopamine determinations under continuous flow conditions with a periodate-selective electrode

Publicações

Dopamine determinations under continuous flow conditions with a periodate-selective electrode

Título
Dopamine determinations under continuous flow conditions with a periodate-selective electrode
Tipo
Artigo em Revista Científica Internacional
Ano
1998
Autores
Lima, JLFC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Montenegro, MCBSM
(Autor)
FFUP
Sales, MGF
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Revista
Vol. 53
Página Final: 213
ISSN: 0047-2166
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-007-GE3
Abstract (EN): The present work reports the dopamine determination in pharmaceutical preparations, which are basically injections, in a flow injection analysis (FIA) system. The used method is based on an oxidation reaction with metaperiodate and a potentiometric detector. For this, a periodate-selective electrode with a tubular configuration, without an internal reference solution and with a membrane of metaperiodate bis(triphenylphosphoranylidene)ammonium (1.3%), 2-nitrophenyl octyl ether (67.5%) and PVC (31.2%) was constructed. This detector was inserted into a double-channel FIA manifold, comprising deionised water in the carrier stream and a 3×10-4 M metaperiodate sodium solution, prepared in a 6.6×10-2 M Na2SO4 solution for the ionic strength adjustment, in the confluent stream. By using a 7 ml/min flow rate, a 70 ¿L injection volume and a 50 cm reactor, a linearity range of potential vs dopamine concentration from 0.008 to 0.273 g/l, with a slope of ¿ 300 mV g l-1, and a reproducibility of ±0.4 mV, were achieved. Interference from common excipients as sodium metabisulphite, sodium chloride, glucose, polyethylene glycol, saccharose and fructose was evaluated performing recoveries over dopamine hydrochloride solutions with several concentration ratios of each possible interferent. Only a slight interference from sodium metabisulphite at 1:1 concentration ratio was recorded. The described system was used for dopamine determinations in injections, presenting a theoretical value of 200 mg/inj.. The average dopamine concentration of 25 determinations was 201.01 mg/inj., with a standard deviation of 3.33 mg/inj.. Recoveries were simultaneously performed over the previous determinations, and average and standard deviation of 101.02% and 1.45% were obtained, respectively.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Tetracycline (TCH), oxytetracycline (OTCH) and chlortetraculine (CTCH) determination using a flow injection potentiometric system (1998)
Artigo em Revista Científica Internacional
Couto, CMCM; Lima, JLFC; Montenegro, MCBSM; Reis, S
Determination of binding constants between ß-blockers and Sodium Dodecyl Sulphate micelles. A fluorimetric and solubility study (1998)
Artigo em Revista Científica Internacional
De Castro, B; Gameiro, P; Guimaraes, C; Lima, JLFC; Reis, S
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-09-27 às 23:13:28 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico