Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Optimized conditions and analytical performance for the determination of Cu in serum and urine samples using a single GFAAS procedure

Publicações

Optimized conditions and analytical performance for the determination of Cu in serum and urine samples using a single GFAAS procedure

Título
Optimized conditions and analytical performance for the determination of Cu in serum and urine samples using a single GFAAS procedure
Tipo
Artigo em Revista Científica Internacional
Ano
2001
Revista
Título: Atomic SpectroscopyImportada do Authenticus Pesquisar Publicações da Revista
Vol. 22
Páginas: 324-330
ISSN: 0195-5373
Classificação Científica
FOS: Ciências exactas e naturais > Física
Outras Informações
ID Authenticus: P-000-VJV
Abstract (EN): The determination of copper in biological samples is of major importance in clinical chemistry and very often, especially when Wilson's disease is suspected, the simultaneous analysis of both serum and urine is necessary. Therefore, a single analytical procedure with proven reliability in the simultaneous determination of copper in both matrices becomes of great practical interest for clinical laboratories. This work describes the optimization and evaluation of a Zeeman-effect background correction GFAAS method. It differs only in the prior dilution of the serum samples (1+24) and allows the determination of copper in both serum and urine samples with proven accuracy, precision, and robustness. The method provides a limit of detection of 0.98 mug/L, a limit of quantification of 3.3 mug/L, and a characteristic mass of about 23 pg. Repeatability (%RSD) was 1.3% for a standard solution (20 mug/L), 2.4% for urine (26 mug/L), and 1.4% for serum (29 mug/L) samples. Between-run and between-day reproducibility was typically better than 5%. Accuracy has been assessed using the standard additions method/calibration curves slope ratio, which was 1.057 for serum and 1.023 for urine, and by the analysis of commercial control samples. Additional evaluation of the results obtained in the determination of copper in serum was made by comparison with Flame AAS analysis.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 7
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Sequential preconcentration for the ETAAS determination of Pd in human urine (2002)
Artigo em Revista Científica Internacional
Costa, RCC; Almeida, AA; Araujo, AN; Silva, VL
Quantification of Ag, Co, Si, and Zn in port wine by atomic absorption spectrometry (1995)
Artigo em Revista Científica Internacional
Soares, ME; Bastos, ML; Ferreira, MA
DETERMINATION OF COPPER IN PORT-WINE AND MADEIRA WINE BY ELECTROTHERMAL ATOMIZATION AAS (1994)
Artigo em Revista Científica Internacional
ALMEIDA, AA; CARDOSO, MI; LIMA, JLFC

Ver todas (12)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-08-01 às 02:55:02 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias