Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > A novel and low cost acoustic based probe for local pulse wave velocity estimation: Experimental characterization and in-vivo feasibility

Publicações

A novel and low cost acoustic based probe for local pulse wave velocity estimation: Experimental characterization and in-vivo feasibility

Título
A novel and low cost acoustic based probe for local pulse wave velocity estimation: Experimental characterization and in-vivo feasibility
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2013
Autores
Pereira, HC
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Maldonado, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Pereira, T
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Contente, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Almeida, V
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Pereira, T
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Simoes, JB
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Cardoso, J
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Correia, C
(Autor)
FCUP
Ata de Conferência Internacional
Páginas: 78-88
International Conference on Biomedical Electronics and Devices, BIODEVICES 2013
Barcelona, 11 February 2013 through 14 February 2013
Indexação
Outras Informações
ID Authenticus: P-008-B0K
Abstract (EN): The use of local pulse wave velocity (PWV) as an independent risk factor for cardiovascular events and as a marker of atherosclerosis has been gained clinical relevance over the years. A novel acoustic double headed probe for non-invasive measurement of the local PWV is presented in this paper. The PWV is assessed in one single location and involves the determination of time delay between the signals acquired simultaneously by two acoustic sensors, placed ¿11 mm apart. Several tests were performed in special purposes test bench systems in order to characterize the acoustic probe (AP) regarding the existence of crosstalk between the transducers, repeatability, waveform analysis and also its time resolution. Results demonstrate the effectiveness of the AP in acquiring repeatedly the same waveform, with the possibility to measure higher PWV (14 m/s), with a relative error less than 5%, when using two uncoupled APs. In-vivo acquisitions were also carried out with the AP in the carotid artery of 17 healthy volunteers with the intention of local PWV and other hemodynamic parameters estimation, such as left ventricular ejection time (LVET). For the total of subjects' sample, the obtained mean carotid PWV was 2.96±1.08 m/s and the LVET mean value was 288.59±21.42 ms.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-07-30 às 08:53:10 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias