Go to:
Logótipo
You are in:: Start > Publications > View > Potentiometric behaviour of ion selective electrodes based on iron porphyrins: The influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations
Map of Premises
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática
Publication

Potentiometric behaviour of ion selective electrodes based on iron porphyrins: The influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations

Title
Potentiometric behaviour of ion selective electrodes based on iron porphyrins: The influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations
Type
Article in International Scientific Journal
Year
2006
Authors
Emilia M G Santos
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Alberto N Araujo
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Cristina M C M Couto
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conceicao C B S M Montenegro
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 42 No. 5
Pages: 535-542
ISSN: 0731-7085
Publisher: Elsevier
Indexing
Scientific classification
FOS: Natural sciences > Chemical sciences
CORDIS: Health sciences
Other information
Authenticus ID: P-004-G2G
Resumo (PT): The potentiometric response characteristics of diclofenac selective electrodes based on Fe(III) tetraphenylporphyrin-chloride (Fe(III)TPP-Cl) and Fe(III) tetrakis(pentafluorophenyl)porphyrin-chloride (Fe(III)TPFPP-Cl) in different mediator solvents and ionic additives are compared. The sensitivity, working range, detection limit, response mechanism, and selectivity of the membrane sensor show a significant dependence on the type of carrier substituent and on the pH value of the sample solution. Studies performed with different amounts of cationic additive (tetra-n-octylammoniumbromide (TOABr)) and anionic additive (sodium tetraphenylborate (NaTPB)) in the membranes allowed the determination of the potentiometric mechanism of action of the used metalloporphyrins. For the analysis of real samples, Fe(III)TPFPP-Cl (type G), prepared in o-NPOE, incorporating 10 mol% of TOABr, was used. This potentiometric unit presented a linear response towards diclofenac concentrations between 10−5 and 10−2 mol l−1 ( I = 0.1 mol l−1) and slopes of about −59 mV dec−1, exhibiting a response time of 10 s in a buffered solution of ammonia–ammonium sulphate with pH 9.9. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was carried out by direct potentiometry and the obtained results were compared to those provided by HPLC, presenting relative errors inferior to 1.0%. <br> <br> Keywords: Diclofenac; Ion selective electrodes; Potentiometry; Iron porphyrins <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TGX-4KD5BTX-1&_user=2460038&_coverDate=11%2F16%2F2006&_rdoc=3&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235266%232006%23999579994%23636174%23FLA%23display%23Volume)&_cdi=5266&_sort=d&_docanchor=&_ct=18&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=49e00dc7844f6697d858c44e00d51535"> Texto integral</a> <br> <br>
Abstract (EN): The potentiometric response characteristics of diclofenac selective electrodes based on Fe(III) tetraphenylporphyrin-chloride (Fe(III)TPP-Cl) and Fe(III) tetrakis(pentafluorophenyl)porphyrin-chloride (Fe(III)TPFPP-Cl) in different mediator solvents and ionic additives are compared. The sensitivity, working range, detection limit, response mechanism, and selectivity of the membrane sensor show a significant dependence on the type of carrier substituent and on the pH value of the sample solution. Studies performed with different amounts of cationic additive (tetra-n-octylammoniumbromide (TOABr)) and anionic additive (sodium tetraphenylborate (NaTPB)) in the membranes allowed the determination of the potentiometric mechanism of action of the used metalloporphyrins. For the analysis of real samples, Fe(III)TPFPP-Cl (type G), prepared in o-NPOE, incorporating 10 mol% of TOABr, was used. This potentiometric unit presented a linear response towards diclofenac concentrations between 10(-5) and 10(-2) mol l(-1) (l = 0.1 mol l(-1)) and slopes of about -59 mV dec(-1), exhibiting a response time of 10 s in a buffered solution of ammonia-ammonium sulphate with pH 9.9. The potentiometric analysis of sodium diclofenac in pharmaceutical formulations was carried out by direct potentiometry and the obtained results were compared to those provided by HPLC, presenting relative errors inferior to 1.0%.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same scientific areas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster in a National Conference
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Another Publication in an International Scientific Journal
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Article in International Scientific Journal
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor

See all (159)

Of the same journal

Modelling skin wound healing angiogenesis: A review (2019)
Another Publication in an International Scientific Journal
Guerra, A; Belinha, J; Renato Natal Jorge
Hybrid MS/NMR methods on the prioritization of natural products: Applications in drug discovery (2018)
Another Publication in an International Scientific Journal
Nelson G. M. Gomes; David M Pereira; Patricia Valentao; Paula B Andrade
Application of sequential injection analysis to pharmaceutical analysis (2006)
Another Publication in an International Scientific Journal
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Article in International Scientific Journal
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor
VITAMIN-B1 AND VITAMIN-B6 TUBULAR ELECTRODES AS FIA DETECTORS - THEIR USE IN THE ANALYSIS OF PHARMACEUTICAL PRODUCTS (1991)
Article in International Scientific Journal
LIMA, JLFC; MONTENEGRO, MCBSM; SILVA, AMR

See all (67)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-08-24 at 15:01:09 | Acceptable Use Policy | Data Protection Policy | Complaint Portal