Go to:
Logótipo
You are in:: Start > Publications > View > Multi-syringe flow injection system with in-line pre-concentration for the determination of total phenolic compounds
Map of Premises
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática
Publication

Multi-syringe flow injection system with in-line pre-concentration for the determination of total phenolic compounds

Title
Multi-syringe flow injection system with in-line pre-concentration for the determination of total phenolic compounds
Type
Article in International Scientific Journal
Year
2005
Authors
Oliveira, HM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Segundo, MA
(Author)
REIT
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Reis, S
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Title: Mikrochimica ActaImported from Authenticus Search for Journal Publications
Vol. 150 No. 2
Pages: 187-196
ISSN: 0026-3672
Publisher: Springer Nature
Indexing
Scientific classification
FOS: Natural sciences > Chemical sciences
CORDIS: Health sciences
Other information
Authenticus ID: P-000-35G
Resumo (PT): A multi-syringe flow injection system for the determination of total phenolics based on the 4-aminoantipyrine reaction is proposed. In-line preconcentration using solid-phase extraction was implemented, offering an environmentally friendly alternative to organic solvent extraction performed in the batch procedure and in previously described flow methodologies. Therefore, phenolic compounds were retained in Amberlite XAD4 resin using acidic conditions. The elution was carried out using 0.10molL–1 NaOH solution, promoting the ionisation of the retained phenolic compounds, and thus their desorption. Since different elution profiles were obtained for several phenol derivatives, the calibration curves were established using the peak area as analytical signal. Moreover, a dynamic calibration range was applied by using a variable sample volume (0.500–6.00mL) and calibration curves based on the mass of phenol retained in the pre-concentration column. A methodology based on a fixed sample volume (24.0mL) was also proposed for determination at concentration levels below 50µgL–1. A limit of detection of 52ng of phenol (9 or 2µgL–1) was achieved with a sampling frequency of 10–16h–1 for the variable volume method and 4h–1 for the fixed volume method. The application of the proposed methodology to reference material provided results that were within the certified acceptance limits. <br> <br> Key words: Multi-syringe; phenolic compounds; solid phase extraction; pre-concentration; spectrophotometry <br> <a target="_blank" href="http://www.springerlink.com/content/jm8n64l62152u825/?p=31baf3f8bf5f4527b72eb7ebf5b33a21&pi=12"> Texto integral</a> <br> <br>
Abstract (EN): A multi-syringe flow injection system for the determination of total phenolics based on the 4-amino-antipyrine reaction is proposed. In-line preconcentration using solid-phase extraction was implemented, offering an environmentally friendly alternative to organic solvent extraction performed in the batch procedure and in previously described flow methodologies. Therefore, phenolic compounds were retained in Amberlite XAD4 resin using acidic conditions. The elution was carried out using 0.10 mol L-1 NaOH solution, promoting the ionisation of the retained phenolic compounds, and thus their desorption. Since different elution profiles were obtained for several phenol derivatives, the calibration curves were established using the peak area as analytical signal. Moreover, a dynamic calibration range was applied by using a variable sample volume (0.500-6.00 mL) and calibration curves based on the mass of phenol retained in the pre-concentration column. A methodology based on a fixed sample volume (24.0 mL) was also proposed for determination at concentration levels below 50 mu g L-1. A limit of detection of 52 ng of phenol (9 or 2 mu g L-1) was achieved with a sampling frequency of 10-16 h(-1) for the variable volume method and 4 h(-1) for the fixed volume method. The application of the proposed methodology to reference material provided results that were within the certified acceptance limits.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same scientific areas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster in a National Conference
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Another Publication in an International Scientific Journal
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM
Volatile composition of Catharanthus roseus (L.) G. Don using solid-phase microextraction and gas chromatography/mass spectrometry (2009)
Article in International Scientific Journal
De Pinho, PG; Rui F Goncalves; Patricia Valentao; David M Pereira; Rosa M Seabra; Paula B Andrade; Mariana Sottomayor

See all (159)

Of the same journal

The development and optimization of a modified single-drop microextraction method for organochlorine pesticides determination by gas chromatography-tandem mass spectrometry (2012)
Article in International Scientific Journal
Virginia C Fernandes; Viswanathan Subramanian; Nuno Mateus; Valentina F Domingues; Cristina Delerue Matos
Multi-syringe flow injection system for the determination of the scavenging capacity of the diphenylpicrylhydrazyl radical in methanol and ethanolic media (2007)
Article in International Scientific Journal
Luis M Magalhaes; Marcela A Segundo; Christophe Siquet; Salette Reis; Jose L F C Lima
Multi-pumping flow system for the determination of nitrite and nitrate in water samples (2008)
Article in International Scientific Journal
Carmen Pons; Joao L M Santos; Jose L F C Lima; Rafael Forteza; Victor Cerda
In situ FT-IR study of the interfacial oxide in the anodic dissolution of silicon (1997)
Article in International Scientific Journal
C. Fonseca; F.Ozanam; J.N.Chazalviel

See all (17)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-08-24 at 05:01:31 | Acceptable Use Policy | Data Protection Policy | Complaint Portal