Go to:
Logótipo
You are in:: Start > Publications > View > Near Infrared Reflectance Spectroscopy Coupled to Chemometrics as a Cost-Effective, Rapid, and Non-Destructive Tool for Fish Fraud Control: Monitoring Source, Condition, and Nutritional Value of Five Common Whitefish Species
Map of Premises
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática
Publication

Near Infrared Reflectance Spectroscopy Coupled to Chemometrics as a Cost-Effective, Rapid, and Non-Destructive Tool for Fish Fraud Control: Monitoring Source, Condition, and Nutritional Value of Five Common Whitefish Species

Title
Near Infrared Reflectance Spectroscopy Coupled to Chemometrics as a Cost-Effective, Rapid, and Non-Destructive Tool for Fish Fraud Control: Monitoring Source, Condition, and Nutritional Value of Five Common Whitefish Species
Type
Article in International Scientific Journal
Year
2021
Authors
Goncalves, DB
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Santos, CSP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pinho, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Queiros, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vaz, PD
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bloore, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Satta, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Kovacs, Z
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Casal, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Hoffmann, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 104
Pages: 53-60
ISSN: 1060-3271
Publisher: AOAC INTERNATIONAL
Indexing
Other information
Authenticus ID: P-00T-PBT
Abstract (EN): Fish fraud is a problematic issue for the industry. For it to be properly addressed will require the use of accurate, rapid, and cost-effective tools. In this work, near infrared reflectance spectroscopy (NIRS) was used to predict nutritional values (protein, lipids, and moisture) as well as to discriminate between sources (farmed vs. wild fish) and conditions (fresh or defrosted fish). Samples of five whitefish species-Alaskan pollock (Gadus chalcogrammu), Atlantic cod (G. morhua), European plaice (Pleuronectes platessa), common sole (Solea solea), and turbot (Psetta maxima)-including farmed, wild, fresh, and frozen ones, were scanned by a low-cost handheld near infrared reflectance spectrometer with a spectral range between 900 and 1700 nm. Several machine learning algorithms were explored for both regression and classification tasks, achieving precisions and coefficients of determination higher than 88% and 0.78, respectively. Principal component analysis (PCA) was used to cluster samples according to classes where good linear discriminations were denoted. Loadings from PCA revealed bands at 1150, 1200, and 1400 nm as the most discriminative spectral regions regarding classification of both source and condition, suggesting the absorbance of OH, CH, CH2, and CH3 groups as the most important ones. This study shows the use of NIRS and both linear and non-linear learners as a suitable strategy to address fish fraud and fish QC.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Use of Flow Injection Multisite Detection as a Novel Approach for Blank Signal Correction in a Spectrophotometric Determination. (2005)
Article in International Scientific Journal
Oliveira, Teresa A. C; Mesquita, Raquel B. R.; Lima, José L. F. C; Rangel, Antonio O. S. S.
Stability of Chlorophenols and Their Acetylated Derivatives in Water: Sample Storage Procedures (2014)
Article in International Scientific Journal
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Pedro N Carvalho; Teresa T S D Vasconcelos
Sequential determination of salicylic and acetylsalicylic acids by amperometric multisite detection flow injection analysis. (2002)
Article in International Scientific Journal
Catarino RI; Garcia MB; Lapa RA; Lima JL; Barrado E

See all (9)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-10-02 at 14:02:58 | Acceptable Use Policy | Data Protection Policy | Complaint Portal