Abstract (EN):
The main goal of this work is to evaluate the response of the diagonals members of steel lattice towers with circular profiles cross-sections, under the wind load determined according to the current regulation EN1991-1-4. For this study, it has been developed a program in VBA using Excel for the evaluation of the response due to vortex shedding induced vibrations and possible failure due to fatigue. A formulation is proposed is for the mitigation or supressing of the amplitudes of vibration, using the Ansys Fluent software for testing. The results obtained of applying small fins in the center section of certain diagonals of the telecommunication tower, with potential to failure due to vortex shedding in the perpendicular direction of wind load, are expected to minimize the damage due to fatigue and increase the expected life time of the structure.
Language:
English
Type (Professor's evaluation):
Scientific
No. of pages:
2