Go to:
Logótipo
You are in:: Start > Publications > View > Tratamento de Humidades Ascensionais em Igrejas. Estudo de Caso
Map of Premises
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática
Publication

Tratamento de Humidades Ascensionais em Igrejas. Estudo de Caso

Title
Tratamento de Humidades Ascensionais em Igrejas. Estudo de Caso
Type
Thesis
Year
2012
Authors
Ana Mafalda Ribeiro Gaspar
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
Vasco Peixoto de Freitas (Orientador)
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Scientific classification
FOS: Engineering and technology > Civil engineering
Other information
Resumo (PT): A presença de humidade nos elementos de construção é uma das principais causas de degradação de edifícios, nomeadamente a ação da humidade ascensional em paredes de edifícios antigos de interesse histórico. A água proveniente do solo migra através dos materiais porosos, por capilaridade, levando ao aparecimento de diversas patologias. Com o intuito de diminuir o efeito da progressão da humidade ascensional em paredes de elevada espessura e heterogeneidade, é desenvolvida a técnica de tratamento designada por ventilação da base das paredes. Pretende-se com este trabalho avaliar o desempenho de sistemas de ventilação da base das paredes em edifícios antigos com valor patrimonial. Neste trabalho foi ainda realizada a instrumentação e monitorização de um sistema de ventilação interior da base das paredes na Igreja de Santa Maria em Vila Boa do Bispo, no Marco de Canaveses, com o intuito de determinar as causas que estão na origem das patologias que surgiram após a implementação desta técnica de tratamento da humidade ascensional. PALAVRAS-CHAVE: Humidade Ascensional, Ventilação da Base das Paredes, Estudo Experimental, Edifícios Históricos.
Abstract (EN): The presence of moisture in building elements is one of the major causes of building degradation, namely the action of rising damp on walls of ancient buildings with historical interest. The water from the soil migrates through the porous materials by osmosis, leading to the appearance of several pathologies. In order to decrease its effect on high thick and heterogenic walls, a treatment technique is developed, known as wall base ventilation. This work aims to evaluate the ventilation systems of the base of walls performance in ancient historic buildings. This work was also carried out a instrumentation and monitoring of an interior system of wall base ventilation in the Santa Maria Church, Vila Boa do Bispo, Marco de Canaveses, in order to find out the causes that are responsible for the emerged pathologies after implementation of this technique for the treatment of rising damp. KEYWORDS: Rising Damp, Wall Base Ventilation, Experimental Study, Historic Buildings.
Language: Portuguese
Type (Professor's evaluation): Scientific
Notes: Tese de Mestrado Integrado ID SDI: 000151127
No. of pages: 129
Documents
We could not find any documents associated to the publication with allowed access.
Related Publications

Of the same authors

Manual de apoio ao projecto de reabilitação de edifícios antigos (2012)
Book
Vasco Peixoto de Freitas; Ana Sofia Guimarães; Aníbal Costa; António Arêde ; A. P. Oliveira de Carvalho; Arlindo Begonha; Carlos Medeiros; Esmeralda Paupério; Eva Barreira; Helena Corvacho; Hipólito de Sousa; João Lopes Porto; João Miranda Guedes; Joaquim Teixeira; José Amorim Faria; Marisa Antunes Quintela; Nuno Ramos; Rui Fernandes Póvoas; Vasco Peixoto De Freitas
Recommend this page Top
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-08-22 at 11:25:10 | Acceptable Use Policy | Data Protection Policy | Complaint Portal