Go to:
Logótipo
You are in:: Start > Publications > View > Sistemas de Ventilação Natural e Mistos em Edifícios de Habitação
Map of Premises
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática
Publication

Sistemas de Ventilação Natural e Mistos em Edifícios de Habitação

Title
Sistemas de Ventilação Natural e Mistos em Edifícios de Habitação
Type
Thesis
Year
2009
Authors
M. PINTO
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vasco Peixoto De Freitas
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Scientific classification
FOS: Engineering and technology > Civil engineering
Other information
Resumo (PT): A qualidade do ambiente interior de edifícios é uma preocupação que acompanha o Homem desde há séculos. Contudo, o aumento do tempo de permanência em edifícios (cerca de 90% das nossas vidas acontece no seu interior) e as novas práticas construtivas, geradoras de potenciais deficiências de carácter higrotérmico, têm vindo a provocar um crescente interesse por esta problemática. A publicação da recente regulamentação portuguesa na área da térmica de edifícios e qualidade do ar veio incrementar os níveis de exigência relativamente ao comportamento higrotérmico da envolvente dos edifícios e as condições de ventilação do ar interior. Em Portugal a maioria dos edifícios de habitação recorre a um sistema de ventilação misto (ventilação mecânica na cozinha e ventilação natural na instalação sanitária). Em face dos potenciais problemas apresentados por este sistema, nomeadamente, a sua intermitência e a possibilidade de inversão de fluxo nas condutas com ventilação natural, levou à prossecução do presente trabalho de investigação que tem como objectivo principal medir o desempenho de um sistema misto de ventilação e propor recomendações práticas. A vasta campanha experimental realizada permitiu realizar, nomeadamente, a caracterização experimental dos dispositivos usados no sistema de ventilação ensaiado e a aplicação do método do gás traçador, com especial ênfase na técnica PFT, ao estudo das renovações horárias do sistema de ventilação proposto. A execução do trabalho experimental permitiu definir exigências de ventilação adaptadas às condições reais do clima interior dos edifícios portugueses e estabelecer regras claras a cumprir por um projecto de ventilação, de forma a satisfazer essas exigências. Palavras-chave: Ventilação; Habitação; Renovações Horárias (RPH); Gás Traçador; Técnica PFT; Técnica do Declive; Sistema Misto de Ventilação.
Abstract (EN): Air quality inside buildings has been a human concern for centuries. Nevertheless, the increased permanence within buildings (approximately 90% of our lives take place indoors) and new building practices, which generate potential hygrothermal deficiencies, have motivated increase interest in this area. The publication of recent Portuguese regulations regarding heating in buildings and air quality has increased the standard regarding hygrothermal behaviour in buildings and the conditions of indoor ventilation. Most residential dwellings in Portugal use a mixed ventilation system (mechanical ventilation in the kitchen and natural ventilation in the bathroom). The potential problems this system presents, namely its intermittent nature and the possibility of reverse flow in the natural ventilation conduits) led to this work. Its main purpose is to measure the performance of a mixed ventilation system and to propose practical recommendations. The vast experimental campaign carried out accomplished a variety of actions in the study of the hourly renewal rates of the proposed ventilation system, namely the experimental characterization of the devices used in the ventilation system trialed and the application of the tracer gas method, with a special emphasis on the PFT technique. The experimental work made it possible to define ventilation demands adapted to the real indoor climate conditions of Portuguese buildings and to establish clear rules that must be followed in a ventilation plan so as to meet those demands. Key words: Ventilation; Dwelling; Air Change Rate (ACH); Tracer Gas; PFT Technique; Decay Technique; Mixed Ventilation System.
Language: Portuguese
Type (Professor's evaluation): Scientific
Notes: ID SDI: 000129055
No. of pages: 355
Documents
We could not find any documents associated to the publication with allowed access.
Related Publications

Of the same authors

Manual de apoio ao projecto de reabilitação de edifícios antigos (2012)
Book
Vasco Peixoto de Freitas; Ana Sofia Guimarães; Aníbal Costa; António Arêde ; A. P. Oliveira de Carvalho; Arlindo Begonha; Carlos Medeiros; Esmeralda Paupério; Eva Barreira; Helena Corvacho; Hipólito de Sousa; João Lopes Porto; João Miranda Guedes; Joaquim Teixeira; José Amorim Faria; Marisa Antunes Quintela; Nuno Ramos; Rui Fernandes Póvoas; Vasco Peixoto De Freitas
Qualidade do ambiente interior em edifícios de habitação (2007)
Article in National Scientific Journal
M. PINTO; J. VIEGAS; V. P. de FREITAS
Influência da Ventilação no Comportamento Higrotérmico dos Edifícios e Implicações Construtivas da Implementação dos sistemas (2007)
Article in International Conference Proceedings Book
V. P. Freitas; M. PINTO; Ana Sofia Guimarães
Caracterização experimental de um sistema de ventilação misto em edifícios de habitação (2006)
Article in International Conference Proceedings Book
M. PINTO; V. P. de FREITAS
Sistemas de Ventilação Natural em Edifícios de Habitação. Requisitos para a sua Modelização (2011)
Article in International Conference Proceedings Book
Vasco Peixoto De Freitas; M. Pinto; J. Viegas; F. Marques da Silva

See all (7)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-09-30 at 19:14:26 | Acceptable Use Policy | Data Protection Policy | Complaint Portal