Go to:
Logótipo
You are in:: Start > Publications > View > Spectrophotometric flow injection determination of total phosphorus in beer using on-line UV/thermal induced digestion
Map of Premises
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática
Publication

Spectrophotometric flow injection determination of total phosphorus in beer using on-line UV/thermal induced digestion

Title
Spectrophotometric flow injection determination of total phosphorus in beer using on-line UV/thermal induced digestion
Type
Article in International Scientific Journal
Year
2000
Authors
Fernandes, SMV
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rangel, AOSS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Journal
Vol. 366
Pages: 112-115
ISSN: 0937-0633
Publisher: Springer X
Other information
Authenticus ID: P-001-1HG
Abstract (EN): A flow injection system for the automatic determination of total phosphorus in beer is described. The developed manifold uses a two-stage photooxidation/thermal digestion procedure together with oxidizing and hydrolyzing reagents to convert all forms of phosphorus compounds to orthophosphate. Polyphosphates are hydrolyzed by acid and heat, and organo-phosphates are digested by UV-catalyzed peroxodisulfate oxidation. The orthophosphate formed is then spectrophotometrically determined by the phosphomolybdenum blue reaction, using stannous chloride as reducing agent. The results obtained for a set of 19 beer samples (with concentrations from 120 to 735 mg P/L) were in good agreement with the reference method, the maximum relative deviation found being 4.7%. Relative standard deviations for ten consecutive determinations were lower than 1.5%, and a detection limit of 1 mg P/L was achieved.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

COLORIMETRIC DETERMINATION OF IRON IN BEER BY FLOW-INJECTION ANALYSIS USING THE MERGING ZONES TECHNIQUE (1995)
Article in International Scientific Journal
FERNANDES, SMV; RANGEL, AOSS; Lima, JLFC
COLORIMETRIC DETERMINATION OF IRON IN BEER BY FLOW INJECTION ANALYSIS USING THE MERGING ZONES TECHNIQUE (1995)
Article in International Scientific Journal
FERNANDES, SMV; RANGEL, AOSS; Lima, JLFC

Of the same journal

Study of the complexation of Cu(II) by fulvic acids extracted from a sewage sludge and its compost (1997)
Article in International Scientific Journal
dasilva, jcge; machado, aasc; pinto, mssds
Study of the acid-base properties of leaf litter extracts (1998)
Article in International Scientific Journal
da Silva, JCGE; Machado, AASC; Ferreira, MA; Rey, F
Monosegmented flow analysis of slow enzymatic reactions: Determination of triglycerides in serum (1998)
Article in International Scientific Journal
Araujo, AN; Catita, JAM; Lima, JLFC; Zagatto, EAG
Flow injection analysis of fluoride in electroplating baths with potentiometric detection (1998)
Article in International Scientific Journal
Perez Olmos, R; Etxebarria, MB; Lima, JLFC; Montenegro, MCBSM

See all (15)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-07-22 at 23:26:06 | Acceptable Use Policy | Data Protection Policy | Complaint Portal