Go to:
Logótipo
You are in:: Start > Publications > View > 96-well microtiter plates for biofouling simulation in biomedical settings
Map of Premises
FC6 - Departamento de Ciência de Computadores FC5 - Edifício Central FC4 - Departamento de Biologia FC3 - Departamento de Física e Astronomia e Departamento GAOT FC2 - Departamento de Química e Bioquímica FC1 - Departamento de Matemática
Publication

96-well microtiter plates for biofouling simulation in biomedical settings

Title
96-well microtiter plates for biofouling simulation in biomedical settings
Type
Article in International Scientific Journal
Year
2014
Authors
J. M. R. Moreira
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
J. S. Teodósio
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
J. D. P. Araújo
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
J. M. Miranda
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
M. Simões
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
L. F. Melo
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
F. J. Mergulhão
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Title: BiofoulingImported from Authenticus Search for Journal Publications
Vol. 30 No. 5
Pages: 535-546
ISSN: 0892-7014
Publisher: Taylor & Francis
Indexing
Other information
Authenticus ID: P-009-GSB
Abstract (EN): Microtiter plates with 96 wells are routinely used in biofilm research mainly because they enable high-throughput assays. These platforms are used in a variety of conditions ranging from static to dynamic operation using different shaking frequencies and orbital diameters. The main goals of this work were to assess the influence of nutrient concentration and flow conditions on biofilm formation by Escherichia coli in microtiter plates and to define the operational conditions to be used in order to simulate relevant biomedical scenarios. Assays were performed in static mode and in incubators with distinct orbital diameters using different concentrations of glucose, peptone and yeast extract. Computational fluid dynamics (CFD) was used to simulate the flow inside the wells for shaking frequencies ranging from 50 to 200 rpm and orbital diameters from 25 to 100 mm. Higher glucose concentrations enhanced adhesion of E. coli in the first 24 h, but variation in peptone and yeast extract concentration had no significant impact on biofilm formation. Numerical simulations indicate that 96-well microtiter plates can be used to simulate a variety of biomedical scenarios if the operating conditions are carefully set.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 12
Documents
File name Description Size
2nd minor revision_manuscript_Gomes et al_Biofouling_highlighted_Post-Print Post-Print version 1345.32 KB
There are documents associated to the publication without allowed access.
Related Publications

Of the same authors

Microtiter plates for biofilm formation in biomedical settings (2012)
Poster in an International Conference
Luciana Gomes; Joana Moreira; Joana Teodósio; Araujo, JDP; Miranda, JM; Simões M; L. F. Melo; Filipe Mergulhão

Of the same journal

Validation of respirometry as a short-term method to assess the efficacy of biocides (2005)
Article in International Scientific Journal
Simoes, M; Pereira, MO; Vieira, MJ
Unsteady state flow and stagnation in distribution systems affect the biological stability of drinking water (2010)
Article in International Scientific Journal
Manuel, CM; Nunes, OC; Melo, LF
The impact of potassium peroxymonosulphate and chlorinated cyanurates on biofilms of Stenotrophomonas maltophilia: effects on biofilm control, regrowth, and mechanical properties (2023)
Article in International Scientific Journal
Inês Gomes; Isabel M. Oliveira; Simões M; A. Plácido; Peter Eaton; Lúcia C. Simões
The effects of metabolite molecules produced by drinking water-isolated bacteria on their single and multispecies biofilms (2011)
Article in International Scientific Journal
Lucia Chaves Simoes; Manuel Simoes; Maria Joao Vieira
The effects of glutaraldehyde on the control of single and dual biofilms of Bacillus cereus and Pseudomonas fluorescens (2011)
Article in International Scientific Journal
Lucia C Simoes; Madalena Lemos; Paula Araujo; Ana Margarida Pereira; Manuel Simoes

See all (39)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Ciências da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-09-27 at 23:22:36 | Acceptable Use Policy | Data Protection Policy | Complaint Portal