Go to:
Logótipo
Você está em: Start > Publications > View > Extensional flow of blood analog solutions in microfluidic devices
Publication

Extensional flow of blood analog solutions in microfluidic devices

Title
Extensional flow of blood analog solutions in microfluidic devices
Type
Article in International Scientific Journal
Year
2011
Authors
Sousa, PC
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Pinho, FT
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Oliveira, MSN
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Alves, MA
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Journal
Title: BiomicrofluidicsImported from Authenticus Search for Journal Publications
Vol. 5
Final page: 014108
ISSN: 1932-1058
Indexing
Scientific classification
FOS: Engineering and technology > Nano-technology
Other information
Authenticus ID: P-002-TFD
Abstract (EN): In this study, we show the importance of extensional rheology, in addition to the shear rheology, in the choice of blood analog solutions intended to be used in vitro for mimicking the microcirculatory system. For this purpose, we compare the flow of a Newtonian fluid and two well-established viscoelastic blood analog polymer solutions through microfluidic channels containing both hyperbolic and abrupt contractions/expansions. The hyperbolic shape was selected in order to impose a nearly constant strain rate at the centerline of the microchannels and achieve a quasihomogeneous and strong extensional flow often found in features of the human microcirculatory system such as stenoses. The two blood analog fluids used are aqueous solutions of a polyacrylamide (125 ppm w/w) and of a xanthan gum (500 ppm w/w), which were characterized rheologically in steady-shear flow using a rotational rheometer and in extension using a capillary breakup extensional rheometer (CaBER). Both blood analogs exhibit a shear-thinning behavior similar to that of whole human blood, but their relaxation times, obtained from CaBER experiments, are substantially different (by one order of magnitude). Visualizations of the flow patterns using streak photography, measurements of the velocity field using microparticle image velocimetry, and pressure-drop measurements were carried out experimentally for a wide range of flow rates. The experimental results were also compared with the numerical simulations of the flow of a Newtonian fluid and a generalized Newtonian fluid with shear-thinning behavior. Our results show that the flow patterns of the two blood analog solutions are considerably different, despite their similar shear rheology. Furthermore, we demonstrate that the elastic properties of the fluid have a major impact on the flow characteristics, with the polyacrylamide solution exhibiting a much stronger elastic character. As such, these properties must be taken into account in the choice or development of analog fluids that are adequate to replicate blood behavior at the microscale. (C) 2011 American Institute of Physics. [doi: 10.1063/1.3567888]
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 19
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Efficient microfluidic rectifiers for viscoelastic fluid flow (2010)
Article in International Scientific Journal
Sousa, PC; Pinho, FT; Oliveira, MSN; Alves, MA

Of the same scientific areas

Small Precise Pointing Device Utilizing Impact Force Accompanying Quick Deformation of Piezo-Electric Element (1999)
Patent
Higuchi Toshiro; Arvid Bergander; Yamagata Yutaka; Joaquim Gabriel Magalhães Mendes; Riyuu Eiden
Synthesis of poluurethane-urea microcapsules with perfume for textile application (2009)
Poster in an International Conference
Sofia N. Rodrigues; Isabel Martins; Maria Barreiro; V. G. Mata; Alírio E. Rodrigues
Evaluation of surfactants of thyme oil microcapsules prepared by coacervation (2010)
Poster in an International Conference
Isabel Martins; Sofia N. Rodrigues; Maria Barreiro; Alírio E. Rodrigues
Towards a reliable technology for antioxidant capacity and oxidative damage evaluation: Electrochemical (bio)sensors (2011)
Another Publication in an International Scientific Journal
Fatima Barroso, MF; de los Santos Alvarez, N; Delerue Matos, C; Oliveira, MBPP

See all (86)

Of the same journal

Viscoelasticity of blood and viscoelastic blood analogues for use in polydymethylsiloxane in vitro models of the circulatory system (2013)
Article in International Scientific Journal
Laura Campo-Deaño; Roel P. A. Dullens; Dirk G. A. L. Aarts; Fernando T. Pinho; Mónica S. N. Oliveira
Optimization of flow-focusing devices for homogeneous extensional flow (2018)
Article in International Scientific Journal
Pimenta, F; Sousa, RG; Alves, MA
Microfluidic converging/diverging channels optimised for homogeneous extensional deformation (2016)
Article in International Scientific Journal
K. Zografos; F. Pimenta; M. A. Alves; M. S. N. Oliveira
In vitro particulate analogue fluids for experimental studies of rheological and hemorheological behavior of glucose-rich RBC suspensions (2017)
Article in International Scientific Journal
Diana Pinho; Laura Campo Deaño; Rui Lima; Fernando T. Pinho
Human red blood cell behavior under homogeneous extensional flow in a hyperbolic-shaped microchannel (2013)
Article in International Scientific Journal
Yaginuma, T.; Mónica S. N. Oliveira; Rui Lima; Ishikawa, T.; Yamaguchi, T.

See all (9)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Ciências da Nutrição e Alimentação da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-06-27 at 11:27:11 | Acceptable Use Policy | Data Protection Policy | Complaint Portal