Você está em: Start > Publications > View > Distributed generation protection scheme to permit ride-through fault
Publication

Distributed generation protection scheme to permit ride-through fault

Title
Distributed generation protection scheme to permit ride-through fault
Type
Article in International Conference Proceedings Book
Year
2009
Authors
Ramalho, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fiteiro, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
20th International Conference and Exhibition on Electricity Distribution, CIRED 2009
Prague, 8 June 2009 through 11 June 2009
Indexing
Scientific classification
CORDIS: Technological sciences > Engineering > Electrical engineering
Other information
Authenticus ID: P-007-RN7
Abstract (EN): The growing concern about global climate change has led the European Union and the Portuguese Government to set targets for the percentage of electricity to be produced from renewable sources. In order to achieve the defined targets, Distributed Generation (DG) is expected to be increasingly integrated into networks. However, the intermittency of some of those DGs (such as wind energy) may enhance network operating costs or decrease network security. Thus, Network Operators started to concern about these effects and in order to avoid them, new wind parks were required to provide ancillary services to the network. These ancillary services include the ride-through-fault capability. Although some wind parks can already supply ride-through-fault capability to the distribution network (i.e. wind parks with Double Fed Induction Generators (DFIG)), most of them are still largely unable to do so due to the current DG protection scheme. This work concentrates on the development of new settings for the DG protection scheme which aims at allowing DG to provide ride-through fault capability to the distribution network. A DFIG with ride-through-fault capability was modeled on PSCAD/EMTDC and tested under the Portuguese Distributed Generation Protection Scheme Regulation Code. New relay settings for the DG protection scheme are advanced and simulated on PSCAD/EMTDC software in order to permit DGs providing ride-through fault capability to the distribution network. Conclusions of the new relay settings performance are withdrawn and commented on.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same scientific areas

Recolha e tratamento de dados biométricos para a classificação de emoções (2008)
Thesis
Jorge Filipe Pinheiro Guerra de Ribeiro Teixeira; Luis Paulo Reis; Luís Paulo Gonçalves dos Reis; Vasco Hugo Vinhas Gonçalves Moreira; Universidade do Porto. Faculdade de Engenharia
Processadores dedicados : Concepção e realização em sistemas digitais reconfiguráveis (1997)
Thesis
José Carlos dos Santos Alves; José Alfredo Ribeiro da Silva Ma; José Silva Matos

See all (857)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Belas Artes da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-10-03 at 17:16:03 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book