Go to:
Logótipo
Você está em: Start > Publications > View > Determination of transition metals in human hair by high-performance liquid chromatography using sodium hexadecane-sulfonate coated columns
Publication

Determination of transition metals in human hair by high-performance liquid chromatography using sodium hexadecane-sulfonate coated columns

Title
Determination of transition metals in human hair by high-performance liquid chromatography using sodium hexadecane-sulfonate coated columns
Type
Article in International Scientific Journal
Year
1999
Authors
Jun, X
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: TalantaImported from Authenticus Search for Journal Publications
Vol. 50
Pages: 253-259
ISSN: 0039-9140
Publisher: Elsevier
Scientific classification
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-001-3B3
Abstract (EN): A chromatographic method for the determination of transition metals in human hair samples is described. The method involves the separation of Cu, Pb, Zn, Ni, Co, Cd and Mn in a C18 column coated with sodium hexadecane-sulfonate (SHS) and spectrophotometric detection (520 nm) after post-column reaction of the eluted metals with 4-(2-pyridylazo)-resorcinol (PAR). The eluent was a 100 mM tartrate solution adjusted to pH 3.1 with a 2 M sodium hydroxide solution (flow-rate = 1.0 mi min(-1)). A good separation of the eluted metals (specially for Cu/Pb and Zn/Ni) has been achieved. The detection limits, expressed as mu g l(-1), were 2.2 (Cu), 8.0 (Pb), 2.8 (Zn), 1.5 (Ni), 1.5 (Co), 12.0 (Cd), and 1.4 (Mn). A microwave-assisted closed vessel acid digestion procedure with HNO3 + HClO4 (4 + 1 ml) was used for the hair samples solubilisation. Nineteen hair samples were analysed with the proposed method. The results were in good agreement with those obtained by atomic absorption spectrometry (AAS).
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 7
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis (2016)
Another Publication in an International Scientific Journal
Couto, RAS; Lima, JLFC; M. Beatriz Q. Garcia
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Flow injection based methods for fast screening of antioxidant capacity (2009)
Another Publication in an International Scientific Journal
Luis M Magalhaes; Miguel Santos; Marcela A Segundo; Salette Reis; Jose L F C Lima
Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples (2012)
Another Publication in an International Scientific Journal
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Teresa T S D Vasconcelos

See all (193)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Arquitectura da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-07-01 at 12:47:51 | Acceptable Use Policy | Data Protection Policy | Complaint Portal