Go to:
Logótipo
Você está em: Start > Publications > View > Multicommuted flow system for the determination of glucose in animal blood serum exploiting enzymatic reaction and chemiluminescence detection
Publication

Multicommuted flow system for the determination of glucose in animal blood serum exploiting enzymatic reaction and chemiluminescence detection

Title
Multicommuted flow system for the determination of glucose in animal blood serum exploiting enzymatic reaction and chemiluminescence detection
Type
Article in International Scientific Journal
Year
2003
Authors
Pires, CK
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Martelli, PB
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Reis, BF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Saraiva, MLMFS
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 25 No. 5
Pages: 109-114
ISSN: 1463-9246
Indexing
Scientific classification
CORDIS: Health sciences
FOS: Engineering and technology > Other engineering and technologies
Other information
Authenticus ID: P-000-FBD
Resumo (PT): An automatic flow procedure based on multicommutation dedicated for the determination of glucose in animal blood serum using glucose oxidase with chemiluminescence detection is described. The flow manifold consisted of a set of three-way solenoid valves assembled to implement multicommutation. A microcomputer furnished with an electronic interface and software written in Quick BASIC 4.5 controlled the manifold and performed data acquisition. Glucose oxidase was immobilized on porous silica beads (glass aminopropyl) and packed in a minicolumn (15 } 5 mm). The procedure was based on the enzymatic degradation of glucose, producing hydrogen peroxide, which oxidized luminol in the presence of hexacyanoferrate(III), causing the chemiluminescence. The system was tested by analysing a set of serum animal samples without previous treatment. Results were in agreement with those obtained with the conventional method (LABTEST Kit) at the 95% confidence level. The detection limit and variation coefficient were estimated as 12.0 mg l−1 (99.7% confidence level) and 3.5% (n=20), respectively. The sampling rate was about 60 determinations h−1 with sample concentrations ranging from 50 to 600 mg l−1 glucose. The consumptions of serum sample, hexacyanoferrate(III) and luminol were 46 μl, 10.0 mg and 0.2 mg/determination, respectively. <br> <br> <a target="_blank" href="http://www.hindawi.com/journals/jammc/2003/457134.abs.html"> Texto integral</a> <br> <br>
Abstract (EN): An automatic flow procedure based on multicommutation dedicated for the determination of glucose in animal blood serum using glucose oxidase with chemiluminescence detection is described. The flow manifold consisted of a set of three- way solenoid valves assembled to implement multicommutation. A microcomputer furnished with an electronic interface and software written in Quick BASIC 4.5 controlled the manifold and performed data acquisition. Glucose oxidase was immobilized on porous silica beads ( glass aminopropyl) and packed in a minicolumn ( 15 x 5 mm). The procedure was based on the enzymatic degradation of glucose, producing hydrogen peroxide, which oxidized luminol in the presence of hexacyanoferrate( III), causing the chemiluminescence. The system was tested by analysing a set of serum animal samples without previous treatment. Results were in agreement with those obtained with the conventional method ( LABTEST Kit) at the 95% confidence level. The detection limit and variation coefficient were estimated as 12.0 mg l(-1) ( 99.7% confidence level) and 3.5% ( n = 20), respectively. The sampling rate was about 60 determinations h(-1) with sample concentrations ranging from 50 to 600 mg l(-1) glucose. The consumptions of serum sample, hexacyanoferrate( III) and luminol were 46 mul, 10.0 mg and 0.2 mg/ determination, respectively.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

An automatic flow procedure for the determination of 3-hydroxybutyrate in animal serum and plasma (2003)
Article in International Scientific Journal
Pires, CK; Martelli, PB; Reis, BF; Lima, JLFC; Saraiva, MLMFS

Of the same scientific areas

Dispositivo para aquisição e processamento de dados para determinação de massa corporal (2009)
Patent
Mendes, J.; Restivo, M.T.; Amaral, Teresa; Chousal, M.F.; Quintas. M.R.
Consumer perspectives of fresh produce in local food markets (2010)
Summary of Presentation in a National Conference
J.Sampaio; A.Rocha; L. M. Cunha; A.P. Moura
Setting definitions of childhood asthma in epidemiologic studies (2019)
Article in International Scientific Journal
Silva, D; Severo, M; Paciência, I; Rufo, J; Martins, C; Moreira, Pedro; Padrão, Patrícia; Delgado, L; Moreira, André
Journal of Innovation Management - The International Journal on Multidisciplinary Approaches on Innovation| Volume 1 | Issue 1 (2013)
Article in International Scientific Journal
João José Pinto Ferreira; Anne-Laure Mention; Marko Torkkeli
Journal of Innovation Management - The International Journal on Multidisciplinary Approaches on Innovation | Volume 3 | Issue 4 (2015)
Article in International Scientific Journal
João José Pinto Ferreira; Anne-Laure Mention; Marko Torkkeli

See all (19)

Of the same journal

Development of a Multicommutated Flow System with Chemiluminometric Detection for Quantification of Gentamicin in Pharmaceuticals (2010)
Article in International Scientific Journal
Lucia H M L M Santos; Araujo, AN; Boaventura Reis; Montenegro, MCBSM
Design and development of a multichannel potentiometer for monitoring an electrode array and its application in f ow analysis (2002)
Article in International Scientific Journal
Jarbas J. R. Rohwedder; Celio Pasquini; Ivo M. Raimundo Jr; M. Conceição B. S. Montenegro; Alberto N. Araújo; Cristina M. C. M. Couto
Design and development of a multichannel potentiometer for monitoring an electrode array and its application in flow analysis (2002)
Article in International Scientific Journal
Rohwedder, JJR; Pasquini, C; Raimundo, IM; Conceicao, M; Montenegro, BSM; Araujo, AN; Couto, CMCM
An improved leaping detector for flow analysis applied to iron speciation in drugs (2000)
Article in International Scientific Journal
Santos, SRB; Araujo, MCU; Honorato, RS; Zagatto, EAG; Lima, JLFC; Lapa, RAS
Recommend this page Top
Copyright 1996-2024 © Faculdade de Arquitectura da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-10-05 at 14:56:28 | Acceptable Use Policy | Data Protection Policy | Complaint Portal