Go to:
Logótipo
Você está em: Start > Publications > View > Performance simulation of a solar-assisted micro-tri-generation system: Hotel case study
Publication

Performance simulation of a solar-assisted micro-tri-generation system: Hotel case study

Title
Performance simulation of a solar-assisted micro-tri-generation system: Hotel case study
Type
Article in International Scientific Journal
Year
2011
Authors
A. I. Palmero-Marrero
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Armando C. Oliveira
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 6 No. 2
Pages: 309-317
ISSN: 1748-1317
Indexing
INSPEC
Scientific classification
FOS: Engineering and technology > Other engineering and technologies
Other information
Authenticus ID: P-008-11X
Abstract (EN): In this work, a micro-tri-generation system integrated with a solar system is studied. A basic microcogeneration technology [micro-CHP (combined heat and power) system] integrating solar collectors, storage tank, micro-turbine and a thermodynamic cycle based on the organic Rankine cycle (ORC) is combined with an absorption chiller. The heat rejected at the condenser of the micro-CHP system is used for water heating (WH), and the absorption chiller is used for space cooling. Hot water from the solar storage tank is the heat source for the cooling system (absorption chiller) and the micro-CHP system. A heat exchanger is used to transfer heat from the hot water circuit to the power cycle (which uses an organic refrigerant). The micro-CHP system under analysis uses a micro-turbine and an electric generator with a power output of 5 kW. The turbine inlet temperature is 80°C and the working fluid is cyclohexane. The absorption chiller, which is a single-effect water-fired chiller, operates with a lithium bromide and water mixture, and water inlet temperature is between 80 and 100°C. The performance for different solar collector areas and tank capacities was evaluated through a numerical model. A hotel building was used as a case study and the analysis was extended throughout the cooling season, for climatic conditions of different European cities: Athens (Greece), Lisbon (Portugal), Madrid (Spain), Paris (France) and London (UK). The monthly average solar fraction was evaluated for different cases: the micro-CHP system, the cooling system and the micro-tri-generation system with the useful condenser energy used for WH. The solar fraction of the micro-CHP system was low, compared with that of the cooling system, because the efficiency of the micro-CHP system is lower than 7%. However, when the tri-generation system is considered, the monthly average solar fraction is much higher, due to the utilization of the condenser heat. The solar system, cooling system and its components were modelled with the TRNSYS simulation program. The micro-CHP system was modelled with EES software.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Integration of PV Systems into the Urban Environment: A Review of Their Effects and Energy Models (2024)
Another Publication in an International Scientific Journal
A. Rodrigues; Armando C. Oliveira; A. I. Palmero-Marrero
Avanço nas Ciências e Técnicas do Frio - IV (2007)
Book
Clito Afonso; Ana Isabel Marrero; J. F. Silva Gomes; Carlos Alberto Conceição António; Armando C. Oliveira
Thermal and electrical performance assessment of a solar polygeneration system (2020)
Article in International Scientific Journal
Behzad Shahzamanian Sichani; J. Soares; S. Varga; Armando C. Oliveira; Ana Isabel Marrero
Theoretical performance assessment of a multi-effect distillation system integrated with thermal vapour compression unit running on solar energy (2024)
Article in International Scientific Journal
Behzad Shahzamanian Sichani; Varga, S; Soares, J; A. I. Palmero-Marrero; Armando C. Oliveira
Testing of an integrated solar louvre collector (2004)
Article in International Scientific Journal
Ana Isabel Marrero; Armando C. Oliveira

See all (50)

Of the same journal

Theoretical performance assessment of a multi-effect distillation system integrated with thermal vapour compression unit running on solar energy (2024)
Article in International Scientific Journal
Behzad Shahzamanian Sichani; Varga, S; Soares, J; A. I. Palmero-Marrero; Armando C. Oliveira
The energy shift: Towards a renewable future (2007)
Article in International Scientific Journal
Armando C. Oliveira
Temperature influence on the thermal and structural properties of electrodeposited nanostructured black nickel cermet on high conductive C81100 copper (2011)
Article in International Scientific Journal
Ricardo Teixeira; R. Raniero; Renata Simão; Bruno Coelho; Armando C. Oliveira
Temperature influence on the thermal and structural properties of electrodeposited nanostructured black nickel cermet on high conductive C81100 copper (2011)
Article in International Scientific Journal
Teixeira, RLP; Raniero, L; Simao, RA; Coelho, B; Armando C. Oliveira

See all (20)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Arquitectura da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-07-07 at 07:13:57 | Acceptable Use Policy | Data Protection Policy | Complaint Portal