Go to:
Logótipo
Você está em: Start > Publications > View > Single point incremental forming of a facial implant
Publication

Single point incremental forming of a facial implant

Title
Single point incremental forming of a facial implant
Type
Article in International Scientific Journal
Year
2014
Authors
Araujo, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pedro Teixeira
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Montanari, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Silva, MB
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Martins, PAF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Journal
Vol. 38
Pages: 369-378
ISSN: 0309-3646
Publisher: SAGE
Other information
Authenticus ID: P-006-FPA
Abstract (EN): Background: The investigation draws from the fundamentals of the mechanical behaviour of titanium grade 2 to the design and fabrication of facial implants by means of single point incremental forming. Objectives: To provide knowledge on the capabilities and limitations of a new manufacturing technology to fabricate low-cost, patient-specific medical implants. Study design: Rapid fabrication of a simplified model of a facial implant. Methods: Circle grid analysis and its graphical representation in the fracture forming limit diagram combined with finite element modelling are utilized to identify the failure limits and to assist the overall design of the facial implants. Results: Fabrication of facial implants without and with failure by cracking due to excessive thinning of the sheet from where the implant is to be cut. Conclusions: Identification of the major operative parameters that influence fabrication of sound facial implants by means of single point incremental forming.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Principal component analysis in ground reaction forces and center of pressure gait waveforms of people with transfemoral amputation (2016)
Article in International Scientific Journal
Denise Paschoal Soares; Marcelo Peduzzi de Castro; Emilia Assunção Mendes; Leandro Machado
Mandible reconstruction: History, state of the art and persistent problems (2014)
Article in International Scientific Journal
José J Ferreira; Carlos M Zagalo; Marta L Oliveira; André Correia; Ana R Reis
An engineering-based approach for design and fabrication of a customized nasal prosthesis (2015)
Article in International Scientific Journal
Neto, R; Costa-Ferreira A; Leal, N; Machado, M; Ana Reis
Recommend this page Top
Copyright 1996-2024 © Faculdade de Arquitectura da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-07-26 at 23:32:49 | Acceptable Use Policy | Data Protection Policy | Complaint Portal