Go to:
Logótipo
Você está em: Start > Publications > View > Curvature Sensor Based on a Fabry-Perot Interferometer
Publication

Curvature Sensor Based on a Fabry-Perot Interferometer

Title
Curvature Sensor Based on a Fabry-Perot Interferometer
Type
Article in International Conference Proceedings Book
Year
2016
Authors
Monteiro, CS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Ferreira, MS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Kobelke, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Schuster, K
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bierlich, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Frazao, O
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
6th European Workshop on Optical Fibre Sensors
Univ Limerick, Limerick, IRELAND, MAY 31-JUN 03, 2016
Other information
Authenticus ID: P-00K-M2C
Abstract (EN): A curvature sensor based on a Fabry-Perot interferometer is proposed. A capillary tube of silica is fusion spliced between two single mode fibers, producing a Fabry-Perot cavity. The light propagates in air, when passing through the capillary tube. Two different cavities are subjected to curvature and temperature. The cavity with shorter length shows insensitivity to both measurands. The larger cavity shows two operating regions for curvature measurement, where a linear response is shown, with a maximum sensitivity of 18.77pm/m(-1) for the high curvature radius range. When subjected to temperature, the sensing head produces a similar response for different curvature radius, with a sensitivity of 0.87pm/degrees C.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Fiber Fabry-Perot Interferometer for Curvature Sensing (2016)
Article in International Scientific Journal
Monteiro, CS; Ferreira, MS; Susana Silva; Kobelke, J; Schuster, K; Bierlich, J; Frazao, O
Recommend this page Top
Copyright 1996-2024 © Faculdade de Arquitectura da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-10-06 at 07:37:17 | Acceptable Use Policy | Data Protection Policy | Complaint Portal