Assessing the variability of the air change rate through tracer gas measurements

Title
Assessing the variability of the air change rate through tracer gas measurements
Type
Article in International Conference Proceedings Book
Year
2017
Authors
Almeida, RMSF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Eva Barreira
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Moreira, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 831-836
11th Nordic Symposium on Building Physics (NSB)
Trondheim, NORWAY, JUN 11-14, 2017
Indexing
Other information
Authenticus ID: P-00N-7KR
Abstract (EN): The increasing energy concerns across the European Union enhanced the importance of buildings ventilation and pointed out the reduction of energy for ventilation as one of the targets. The measurement of ventilation and leakage rates are therefore necessary to understand buildings performance, especially in mild climate countries where often dwellings ventilation is adventitious and highly influenced by user behaviour. In mild climate countries, natural ventilation is the most common strategy. The air movement is therefore a combined result of pressure differences produced by wind and buoyancy forces, which are both time-dependent. Under these circumstances, one-time measurements of the air change rate, made over short periods, may not be an accurate indicator. An experimental campaign for the evaluation of the air change rate in a Portuguese dwelling was conducted over a period of two months. During this period, tracer gas measurements were performed in two compartments: (R1) living room; and (R2) bedroom. In each, two different boundary conditions were tested: (i) door closed; and (ii) door opened. A total of 132 tests were carried out. The decay technique was used for the quantification of the air change rate. Simultaneously, indoor and outdoor conditions were continuously monitored. The results highlighted the importance of performing several measurements as some variability was found, especially for the open door scenarios. Moreover, the importance of wind speed was also confirmed as the main trigger mechanism in naturally ventilated buildings, especially in the mid-season period where the indoor/outdoor temperature difference is not significant. (C) 2017 The Authors. Published by Elsevier Ltd.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2024 © Faculdade de Arquitectura da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-10-06 at 10:17:03 | Acceptable Use Policy | Data Protection Policy | Complaint Portal