Go to:
Logótipo
Você está em: Start > Publications > View > Fatigue crack growth behaviour of the 6082-T6 aluminium using CT specimens with distinct notches
Publication

Fatigue crack growth behaviour of the 6082-T6 aluminium using CT specimens with distinct notches

Title
Fatigue crack growth behaviour of the 6082-T6 aluminium using CT specimens with distinct notches
Type
Article in International Conference Proceedings Book
Year
2016
Authors
Abilio M P De Jesus
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
A.S.F Alves
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
G. Lesiuk
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Paulo José Tavares
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
Moreira, PMGP
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
Pages: 3272-3279
21st European Conference on Fracture (ECF)
Catania, ITALY, JUN 20-24, 2016
Other information
Authenticus ID: P-00M-AH2
Abstract (EN): This paper presents a study aiming at characterizing the fatigue crack growth behaviour of the 6082-T6 aluminium alloy using standard CT specimens. The fatigue crack growth threshold is also characterized according to the ASTM E 647 standard Besides the standard CT specimens with sharp notches, specimens with initial circular notches were also fatigue tested. The threshold stress intensity factor ranges, Delta K-th, are compared for the distinct notches under study. The fatigue crack propagation rate in the regime II are obtained using the Paris law. A comparison is made between the CT specimens geometries with distinct notches under consideration. The Delta K-th values for the geometry of standard CT specimens present lower values when compared with the geometry of the CT specimens with blunted notches. Copyright (C) 2016 The Authors. Published by Elsevier B.V.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2024 © Faculdade de Arquitectura da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-11-08 at 21:11:29 | Acceptable Use Policy | Data Protection Policy | Complaint Portal