Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Time Effect in Extensional Electrorheological Characterization

Time Effect in Extensional Electrorheological Characterization

Título
Time Effect in Extensional Electrorheological Characterization
Tipo
Artigo em Livro de Atas de Conferência Internacional
Ano
2020-08-21
Autores
Samir Sadek
(Autor)
FEUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Sem AUTHENTICUS Sem ORCID
Hossein Najafabadi
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ata de Conferência Internacional
Páginas: 152-156
7th Iberian Meeting on Rheology (IBEREO) of the Spanish-Group-of-Rheology (GER) and Portuguese-Society-of-Rheology (SPR)
Univ Porto, Porto, PORTUGAL, SEP 04-06, 2019
Outras Informações
ID Authenticus: P-00T-YG6
Resumo (PT):
Abstract (EN): When performing extensional ER tests for the characterization of electro-rheological fluids, the time between applying the electric field and triggering the experiment (delay time) plays an important role in ER behaviour of the sample. The current study investigates the delay time effect in extensional ER characterization. The ER sample used in the measurements is a suspension of cornstarch in olive oil with a concentration of 30 wt%. Fixtures adaptable to the commercial version of the Capillary Breakup Extensional Rheometer (HaakeTM CaBERTM, Thermo Scientific) are designed and fabricated to allow the application of an external electric field aligned with the flow kinematics undergone by the fluid sample while the extensional characterization is taking place. An in-house code developed in Matlab is used to process the images and investigate the filament thinning behaviour of the sample under 3 kV applied voltage and at different delay times (0 s, 10 s, and 40 s). The results show that, under extensional flow, when the voltage is applied, and the delay time between setting the electric field and triggering the experiment is 10 s, the fluid filament breaks. However, if the delay time is increased up to 40 s, then it is observed that the filament does not break anymore. Thus, increasing the time between applying the voltage and triggering the experiment strengthens the structure of the ER sample. According to these results, it can be concluded that the formation of the microstructure due to the presence of the electric field does not occur instantaneously, but instead it is a time-dependent phenomenon.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 5
Documentos
Não foi encontrado nenhum documento associado à publicação.
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Centro de Desporto da Universidade do Porto I Termos e Condições I Acessibilidade I Índice A-Z
Página gerada em: 2025-10-16 às 17:46:01 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico