Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach

On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach

Título
On-line renewable solid-phase extraction hyphenated to liquid chromatography for the determination of UV filters using bead injection and multisyringe-lab-on-valve approach
Tipo
Artigo em Revista Científica Internacional
Ano
2010
Autores
Hugo M Oliveira
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Marcela A Segundo
(Autor)
FFUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Manuel Miro
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Victor Cerda
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 1217 43
Páginas: 3575-3582
ISSN: 0021-9673
Editora: Elsevier
Classificação Científica
FOS: Ciências exactas e naturais > Química
CORDIS: Ciências da Saúde
Outras Informações
ID Authenticus: P-003-6MZ
Resumo (PT): For the first time, an automatic sample pre-treatment/detection method is proposed for the multiclass determination of UV filters (namely, benzophenone-3, ethylhexylmetoxycinnamate, butylmethoxydibenzoylmethane and homosalate) in environmental samples. The new methodology comprises in-line solid-phase extraction (SPE) of the target analytes by exploiting the bead injection (BI) concept in a mesofluidic lab-on-valve (LOV) format, with subsequent determination by liquid chromatography (LC). The proposed microanalytical system, using a multisyringe burette as propulsion unit, automatically performed the overall SPE steps, including the renewal of the sorbent in each analytical cycle to prevent sample cross-contamination and the post-extraction adjustment of the eluate composition to prevent chromatographic band broadening effects. In order to expedite the LC separation, a C18 monolithic column was applied and an accelerated isocratic elution was carried out by using a cationic surfactant as mobile phase additive. The LOV-BI-LC method was proven reliable for handling and analysis of complex matrices, e.g., spiked swimming pool water and seawater, with limits of detection ranging between 0.45 and 3.2 μg L−1 for 9 mL sample volume. Linear calibration was attained up to 160 μg L−1 for homosalate and up to 35 μg L−1 for the other target analytes, with good reproducibility (RSD < 13%, for 5 different SPE columns). The hyphenated scheme is able to process a given sample simultaneously and within the same time frame than the chromatographic separation/determination of the formerly pre-treated sample, providing concentration values every 9 min. Hence, the sample throughput was enhanced up to 33 times when compared with previously reported off-line SPE methods. A drastic reduction in reagent consumption and effluent production was also attained, contributing to the development of an environment-friendly analyzer. <br> <br> Keywords: UV filters; Automation; On-line solid-phase extraction; Lab-on-valve; Bead injection <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TG8-4YPT1RD-2&_user=2460038&_coverDate=05%2F28%2F2010&_rdoc=4&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235248%232010%23987829977%231947685%23FLA%23display%23Volume)&_cdi=5248&_sort=d&_docanchor=&_ct=10&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=1d07f0c05a3e0e01ff4d1f764b551f6e "> Texto integral </a> <br> <br>
Abstract (EN): For the first time, an automatic sample pre-treatment/detection method is proposed for the multiclass determination of UV filters (namely, benzophenone-3, ethylhexylmetoxycinnamate, butylmethoxydibenzoylmethane and homosalate) in environmental samples. The new methodology comprises in-line solid-phase extraction (SPE) of the target analytes by exploiting the bead injection (BI) concept in a mesofluidic lab-on-valve (LOV) format, with subsequent determination by liquid chromatography (LC). The proposed microanalytical system, using a multisyringe burette as propulsion unit, automatically performed the overall SPE steps, including the renewal of the sorbent in each analytical cycle to prevent sample cross-contamination and the post-extraction adjustment of the eluate composition to prevent chromatographic band broadening effects. In order to expedite the LC separation, a C-18 monolithic column was applied and an accelerated isocratic elution was carried out by using a cationic surfactant as mobile phase additive. The LOV-BI-LC method was proven reliable for handling and analysis of complex matrices, e.g., spiked swimming pool water and seawater, with limits of detection ranging between 0.45 and 3.2 mu g L-1 for 9 mL sample volume. Linear calibration was attained up to 160 mu g L-1 for homosalate and up to 35 mu g L-1 for the other target analytes, with good reproducibility (RSD < 13%, for 5 different SPE columns). The hyphenated scheme is able to process a given sample simultaneously and within the same time frame than the chromatographic separation/determination of the formerly pre-treated sample, providing concentration values every 9min. Hence, the sample throughput was enhanced up to 33 times when compared with previously reported off-line SPE methods. A drastic reduction in reagent consumption and effluent production was also attained, contributing to the development of an environment-friendly analyzer.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 8
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Dos mesmos autores

Das mesmas áreas científicas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster em Conferência Nacional
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Outra Publicação em Revista Científica Internacional
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Outra Publicação em Revista Científica Internacional
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Outra Publicação em Revista Científica Internacional
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM

Ver todas (159)

Da mesma revista

Enantiomeric ratios: Why so many notations? (2018)
Outra Publicação em Revista Científica Internacional
M E Tiritan; Carla Fernandes; Maia, AS; Pinto, M; Cass, QB
Chromatographic supports for enantioselective liquid chromatography: Evolution and innovative trends (2022)
Outra Publicação em Revista Científica Internacional
Carla Fernandes; Lima, R; Pinto, MMM; Tiritan M.E.
Ultrathin phenyl-functionalized solid phase microextraction fiber coating developed by sol-gel deposition (2005)
Artigo em Revista Científica Internacional
Azenha, M; Malheiro, C; Silva, AF
Turning cork by-products into smart and green materials for solid-phase extraction - gas chromatography tandem mass spectrometry analysis of fungicides in water (2020)
Artigo em Revista Científica Internacional
Celeiro, M; Vazquez, L; Sergazina, M; Docampo, S; Dagnac, T; Vitor Vilar; Llompart, M
Synthesis of glycylglycine-imprinted silica microspheres through different water-in-oil emulsion techniques (2013)
Artigo em Revista Científica Internacional
Mariana Ornelas; Dianne Loureiro; Maria Joao Araujo; Eduardo Marques; Cristina Dias Cabral; Manuel Azenha; Fernando Silva

Ver todas (137)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Centro de Desporto da Universidade do Porto I Termos e Condições I Acessibilidade I Índice A-Z
Página gerada em: 2025-10-09 às 02:57:57 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico