Measurement of the hygric resistance of concrete blocks with perfect contact interface: influence of the contact area

Título
Measurement of the hygric resistance of concrete blocks with perfect contact interface: influence of the contact area
Tipo
Artigo em Revista Científica Internacional
Ano
2021
Autores
António C. Azevedo
(Autor)
FEUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Sem AUTHENTICUS Sem ORCID
João M. P. Q. Delgado
(Autor)
FEUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Klayne Silva
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
André Leal
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ana Sofia Guimarães
(Autor)
FEUP
Isabel Martins Ribeiro
(Autor)
FEUP
Revista
Vol. 15 1
Páginas: 29-37
ISSN: 1874-1495
Indexação
Publicação em Scopus Scopus - 0 Citações
Outras Informações
ID Authenticus: P-00T-PXN
Resumo (PT):
Abstract (EN): Introduction: Concrete sealing blocks are not only used in Brazil but worldwide. T he knowledge of the material properties in the presence of moisture becomes necessary to study the durability of buildings. Methods: An experimental study was carried out in order to analyse the effect of contact area on the capillary absorption coefficient of concrete samples used in sealing blocks, according to several standards: NBR 9779 (2012), EN 1015-18 (2002), ISO 15148 (2002) and ASTM C1794 (2015). Two types of specimens were analysed; monolithic samples and samples with a perfect contact interface. The monolithic samples were also subjected to axial and radial compression in order to enhance the capacity of masonry. Results: The experimental results for the samples with perfect contact interface indicate that the water absorption before the interface presents similar behaviour to the monolithic samples. However, it is possible to observe a reduction of the absorption rate when water reaches the interface due to the hygric resistance. In other words, the moisture transport is significantly retarded by the existence of an interface, i.e., the discontinuity of moisture content across the interface indicated that there was a difference in capillary pressure across the interface. Also, the interface contact area does not greatly influence the water-resistance values. Conclusion: Finally, the Hygric Resistance values (HR), in multilayer building components, with perfect contact interface are calculated using the ¿knee point¿ methodology. © 2021 Azevedo et al.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Preliminary analysis of the influence of reinforced mortar coating on the compressive strength of clay bricks (2018)
Artigo em Revista Científica Internacional
Ana Sofia Guimarães; J.M.P.Q. Delgado; António Azevedo; Fernando Artur Nogueira; Ricardo Oliveira
Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Centro de Desporto da Universidade do Porto I Termos e Condições I Acessibilidade I Índice A-Z
Página gerada em: 2025-11-21 às 02:44:03 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico