Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Direct Comparison of Cardiac Magnetic Resonance and Multidetector Computed Tomography Stress-Rest Perfusion Imaging for Detection of Coronary Artery Disease

Direct Comparison of Cardiac Magnetic Resonance and Multidetector Computed Tomography Stress-Rest Perfusion Imaging for Detection of Coronary Artery Disease

Título
Direct Comparison of Cardiac Magnetic Resonance and Multidetector Computed Tomography Stress-Rest Perfusion Imaging for Detection of Coronary Artery Disease
Tipo
Artigo em Revista Científica Internacional
Ano
2013
Autores
Bettencourt, N
(Autor)
Outra
Chiribiri, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Schuster, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ferreira, N
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Sampaio, F
(Autor)
Outra
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Pires Morais, G
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Santos, L
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Melica, B
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Ver página do Authenticus Sem ORCID
Rodrigues, A
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Braga, P
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Azevedo L
(Autor)
FMUP
Teixeira, M
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Leite-Moreira AF
(Autor)
FMUP
Silva Cardoso, J
(Autor)
FMUP
Nagel, E
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Gama, V
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Revista
Vol. 61
Páginas: 1099-1107
ISSN: 0735-1097
Editora: Elsevier
Outras Informações
ID Authenticus: P-002-013
Abstract (EN): Objectives This study sought to compare the diagnostic performance of a multidetector computed tomography (MDCT) integrated protocol (IP) including coronary angiography (CTA) and stress-rest perfusion (CTP) with cardiac magnetic resonance myocardial perfusion imaging (CMR-Perf) for detection of functionally significant coronary artery disease (CAD). Background MDCT stress-rest perfusion methods were recently described as adjunctive tools to improve CTA accuracy for detection of functionally significant CAD. However, only a few studies compared these MDCT-IP with other clinically validated perfusion techniques like CMR-Perf. Furthermore, CTP has never been validated against the invasive reference standard, fractional flow reserve (FFR), in patients with suspected CAD. Methods 101 symptomatic patients with suspected CAD (62 +/- 8.0 years, 67% males) and intermediate/high pre-test probability underwent MDCT, CMR and invasive coronary angiography. Functionally significant CAD was defined by the presence of occlusive/subocclusive stenoses or FFR measurements <= 0.80 in vessels >2mm. Results On a patient-based model, the MDCT-IP had a sensitivity, specificity, positive and negative predictive values of 89%, 83%, 80% and 90%, respectively (global accuracy 85%). These results were closely related with those achieved by CMR-Perf: 89%, 88%, 85% and 91%, respectively (global accuracy 88%). When comparing test accuracies using non-inferiority analysis, differences greater than 11% in favour of CMR-Perf can be confidently excluded. Conclusions MDCT protocols integrating CTA and stress-rest perfusion detect functionally significant CAD with similar accuracy as CMR-Perf. Both approaches yield a very good accuracy. Integration of CTP and CTA improves MDCT performance for the detection of relevant CAD in intermediate to high pre-test probability populations. (J Am Coll Cardiol 2013;61:1099-107) (C) 2013 by the American College of Cardiology Foundation
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

The European Society of Cardiology's Cardiologists of Tomorrow The Evolving "Heart Team" Opens International Borders (2015)
Outra Publicação em Revista Científica Internacional
Fontes-Carvalho R; Vidal Perez, R; Poess, J
Statins and aortic stenosis in the context of ratio of low- to high-density lipoprotein cholesterol - Reply (2007)
Outra Publicação em Revista Científica Internacional
Moura LM; Zamorano, JL; Ramos, SF; Barros, IM; Azevedo L; Rocha Goncalves, F; Rajamannan, NM
Simultaneous Transapical Implantation of an Inverted Transcatheter Aortic Valve-in-Ring in the Mitral Position and Transcatheter Aortic Valve Replacement First-in-Human Report (2014)
Outra Publicação em Revista Científica Internacional
Ladeiras-Lopes R; Vouga, L; Braga, P; Paulo, N; Azevedo, AI; Neves, P; Ribeiro, J; Fonseca, M; Gama, V
REPLY: Optimal Guideline-Directed Medical Therapy for Patients With Stable Ischemic Heart Disease (2018)
Outra Publicação em Revista Científica Internacional
Pinho Gomes, AC; Azevedo L; Taggart, DP
Renal Outcomes and the Relative Benefit and Harm of Intensive Treatment of Hypertension (2018)
Outra Publicação em Revista Científica Internacional
Vieira, MB; Magrico, R; Dias, CV; Leitao, L; Neves, JS

Ver todas (39)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Centro de Desporto da Universidade do Porto I Termos e Condições I Acessibilidade I Índice A-Z
Página gerada em: 2025-10-23 às 08:22:08 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico