Flow cytometry assessment of graft-infiltrating lymphocytes can accurately identify acute rejection in kidney transplants

Title
Flow cytometry assessment of graft-infiltrating lymphocytes can accurately identify acute rejection in kidney transplants
Type
Article in International Scientific Journal
Year
2014
Authors
xavier, pdp
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
lema, gl
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
magalhaes, mc
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
teixeira-pinto, a
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
sampaio-norton, s
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
gaiao, s
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
guimaraes, t
(Author)
FCNAUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
oliveira, jgg
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 28
Pages: 177-183
ISSN: 0902-0063
Publisher: Wiley-Blackwell
Scientific classification
FOS: Medical and Health sciences > Clinical medicine
Other information
Authenticus ID: P-009-4GS
Abstract (EN): BackgroundPreviously, we have reported that flow cytometry analysis of fine-needle aspirates can accurately predict rejection in kidney transplants treated with cyclosporine-azathioprine-prednisolone. In this study, we examined this technique's accuracy using current immunosuppression. MethodsKidney transplant recipients were treated with calcineurin inhibitors, mycophenolate mofetil, and prednisolone: 92 remained rejection-free - Group I - and 37 developed acute rejection - Group II. An allograft aspiration specimen and peripheral blood were collected from Group I on post-transplant day 7 and from Group II on the day of clinical rejection. ResultsSignificant changes were seen in both aspiration and peripheral blood samples in several T cell subsets when comparing Groups I and II. A sensitivity of 94.6%, specificity of 85%, and AUC=0.966 were observed through combining CD8DR with CD3CD69 values from aspiration specimen; the corresponding AUC in peripheral blood was 0.847. Irreversible rejections displayed a significantly higher activation score (p=0.024). ConclusionsFlow cytometry analysis of aspiration specimen achieved high diagnostic performance in renal transplants through studying CD8DR and CD3CD69 under current immunosuppressive therapy. Peripheral blood analysis, although not significant, showed the same trend. The activation score anticipated the irreversibility of rejection. The data suggest this test, through an easily tolerated technique, merits further diagnostic use.
Language: English
Type (Professor's evaluation): Scientific
Contact: marilu@med.up.pt
No. of pages: 7
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The stability of the gut, oral, and circulating microbiomes in living kidney donors: A 2 years prospective study (2023)
Another Publication in an International Scientific Journal
Araujo, R; Ribas, AM; Sampaio, S; Silva, N; Campos, J; Pestana M; Benedita Sampaio-Maia
Flow cytometry assessment of graft-infiltrating lymphocytes can accurately identify acute rejection in kidney transplants (2014)
Article in International Scientific Journal
Xavier, PDP; Lema, GL; Magalhaes, MC; Teixeira Pinto, A; Sampaio Norton, S; Sergio Gaiao; guimaraes, jt; José Oliveira
Conversion from sirolimus to everolimus in kidney transplant recipients receiving a calcineurin-free regimen (2011)
Article in International Scientific Journal
Carvalho, C; Luís Coentrão; Bustorff, M; Patricio, E; Sampaio, S; Santos, J; José Oliveira; Pestana M
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-17 at 21:31:17 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book