Go to:
Logótipo
Você está em: Start > Publications > View > Non-contact Pulse Wave Velocity Assessment Using Optical Methods
Map of Premises
Principal
Publication

Non-contact Pulse Wave Velocity Assessment Using Optical Methods

Title
Non-contact Pulse Wave Velocity Assessment Using Optical Methods
Type
Article in International Conference Proceedings Book
Year
2011
Authors
silva, as
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
salazar, aj
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
borges, cm
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
correia, mv
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 246-257
4th International Joint Conference on Biomedical Engineering Systems and Technologies, BIOSTEC 2011
Rome, 26 January 2011 through 29 January 2011
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge
Other information
Authenticus ID: P-008-BKT
Abstract (EN): The clinical relevance of pulse wave velocity (PWV), as an indicator of cardiac risk associated to arterial stiffness, has gained clinical relevance over the last years. Optic sensors are an attractive instrumental solution for this type of measurement due to their truly non-contact operation capability, which has the potential of an interference free measurement. The nature of the optically originated signals, however, poses new challenges to the designer, either at the probe design level as at the signal processing required to extract the timing information that yields PWV. In this work we describe the construction of two prototype optical probes and discuss their evaluation using three algorithms for pulse transit time (PTT) evaluation. Results, obtained in a dedicated test bench, that is also described, demonstrate the possibility of measuring pulse transit times as short as 1ms with less than 1% error. © Springer-Verlag Berlin Heidelberg 2013.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Co-activation of upper limb muscles during reaching in post-stroke subjects: An analysis of the contralesional and ipsilesional limbs (2014)
Article in International Scientific Journal
silva, cc; silva, a; sousa, asp; pinheiro, ar; bourlinova, c; silva, as; salazar, aj; borges, cm; crasto, c; correia, mv; vilas-boas, jp; santos, rs
W2M2: WIRELESS WEARABLE MODULAR MONITOR A Multifunctional Monitoring System for Rehabilitation (2012)
Article in International Conference Proceedings Book
salazar, aj; silva, as; silva, c; borges, cm; correia, mv; santos, rs; vilas-boas, jp
WIMU: WEARABLE INERTIAL MONITORING UNIT A MEMS-based Device for Swimming Performance Analysis (2011)
Article in International Conference Proceedings Book
silva, as; salazar, aj; correia, mf; borges, cm
Compensatory Movement Detection through Inertial Sensor Positioning for Post-stroke Rehabilitation (2012)
Article in International Conference Proceedings Book
borges, cm; silva, c; salazar, aj; silva, as; correia, mv; santos, rs; vilas-boas, jp
An initial experience in wearable monitoring sport systems (2010)
Article in International Conference Proceedings Book
salazar, aj; silva, as; borges, cm; correia, mv
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-14 at 20:15:53 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book