Go to:
Logótipo
Você está em: Start > Publications > View > Assessment of percutaneous closure for decannulation of veno-arterial extracorporeal membrane oxygenation: A retrospective study
Map of Premises
Principal
Publication

Assessment of percutaneous closure for decannulation of veno-arterial extracorporeal membrane oxygenation: A retrospective study

Title
Assessment of percutaneous closure for decannulation of veno-arterial extracorporeal membrane oxygenation: A retrospective study
Type
Article in International Scientific Journal
Year
2024
Authors
Martins-Fernandes, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rocha-Neves, J
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Ferreira, AR
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Martins, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sergio Gaiao
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Paiva, J-A
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
ISSN: 1129-7298
Publisher: WICHTIG PUBLISHING
Other information
Authenticus ID: P-017-GHH
Abstract (EN): Background: Despite the evidence supporting the use of Perclose Proglide (R) (PP) suture-mediated vascular closure devices in various clinical scenarios, limited evidence exists regarding its role in percutaneous arterial closure of the femoral artery after venoarterial extracorporeal membrane oxygenation (VA-ECMO). Compared to conventional methods, this study evaluates the effectiveness and complications of bedside percutaneous femoral artery closure using Perclose ProGlide (PP) for VA-ECMO decannulation. Methods: Retrospective cohort of consecutive patients managed with mechanical circulatory support VA-ECMO for refractory cardiogenic shock, who survived decannulation between January 2017 and August 2023. A comparison between PP and other decannulation strategies was established to evaluate the effectiveness and procedure-related complications of bedside percutaneous femoral artery closure using a PP with a post-closure technique compared to conventional approaches of surgical and manual decannulation. Results: Among 122 patients decannulated from VA-ECMO with a mean age of 48.6 +/- 13.1 and 78 (63.9) males, 49.2% comprised the PP group. Despite the older age (p = 0.021) and higher prevalence of arterial hypertension (p = 0.045), the PP group had a larger number of patients free from decannulation-related adverse events. Additionally, a higher haemoglobin level 24 h post decannulation (p = 0.047), with no difference in terms of transfusion of red blood cells between groups (p = 0.263) was found. The pseudoaneurysm was the most frequently reported complication, while the arterial cannulation surgical wound site infection was only documented in the open repair subgroup. A trend towards reduced Intensive Care (ICU) and hospital length of stay after decannulation was noted, although it did not reach statistical significance. There was no difference in mortality between both groups and no procedure-related deaths occurred. A mean of 2.7 PP devices were required to achieve complete haemostasis in the PP cohort, where technical failure was documented in four cases (6.7%). Conclusions: Bedside Percutaneous decannulation of VA-ECMO using a PP device with a post-closure technique is safe and reliable for achieving effective haemostasis, with fewer vascular complications than conventional approaches and a low device failure rate.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Vascular access versus the effect of statins on inflammation and fibrinolysis in renal dialysis patients (2013)
Article in International Scientific Journal
Maria do Sameiro Faria; Sandra Ribeiro; Petronila Rocha Pereira; Vasco Miranda; Alexandre Quintanilha; Flavio Reis; Elisio Costa; Luis Belo; Alice Santos Silva
Type of vascular access and location in online hemodiafiltration and its association with patient's perception of health-related quality of life (2014)
Article in International Scientific Journal
Alexandra Moura; Jose Madureira; Pablo Alija; Joao Carlos Fernandes; Jose Gerardo Oliveira; Martin Lopez; Madalena Filgueiras; Leonilde Amado; Maria Sameiro Faria; Vasco Miranda; Margarida Vieira; Alice Santos Silva; Elisio Costa
Cross-talk between inflammation, coagulation/fibrinolysis and vascular access in hemodialysis patients (2008)
Article in International Scientific Journal
Costa, E; Rocha, S; Rocha Pereira, P; Castro, E; Reis, F; Teixeira, F; Miranda, V; Do Sameiro Faria; Loureiro, A; Quintanilha, A; Belo, L; Santos Silva, A
Cross-cultural validation of the Short-Form Vascular Access Questionnaire (2023)
Article in International Scientific Journal
Barros, JP; Fonseca, J; Pinto, R; Pratas, J; Cruz Correia, R
Arteriovenous access banding revisited (2017)
Article in International Scientific Journal
Teixeira, G.; Almeida, P.; Sousa, C.; Paulo Teles; De Sousa, P.; Loureiro, L.; Teixeira, S.; Rego, D.; Almeida, R.; Norton de Matos, A.